IEC TS 60034-27-2:2012

IEC TS 60034-27-2:2012

March 2012
Technical specification Cancelled

Rotating electrical machines - Part 27-2: On-line partial discharge measurements on the stator winding insulation of rotating electrical machines

IEC/TS 60034-27-2:2012(E) provides a common basis for:- measuring techniques and instruments;- the arrangement of the installation;- normalization and sensitivity assessment;- measuring procedures;- noise reduction;- the documentation of results;- the interpretation of results with respect to partial discharge on-line measurements on the stator winding insulation of non-converter driven rotating electrical machines with rated voltage of 3 kV and up. Keywords: rotating electrical machines

Main informations

Collections

International IEC standards

Publication date

March 2012

Number of pages

55 p.

Reference

IEC TS 60034-27-2:2012

Print number

1 - 13/04/2012
Sumary
Rotating electrical machines - Part 27-2: On-line partial discharge measurements on the stator winding insulation of rotating electrical machines

IEC/TS 60034-27-2:2012(E) provides a common basis for:
- measuring techniques and instruments;
- the arrangement of the installation;
- normalization and sensitivity assessment;
- measuring procedures;
- noise reduction;
- the documentation of results;
- the interpretation of results with respect to partial discharge on-line measurements on the stator winding insulation of non-converter driven rotating electrical machines with rated voltage of 3 kV and up. Keywords: rotating electrical machines
Standard replaced by (1)
IEC 60034-27-2:2023
December 2023
International standard Current
Rotating electrical machines - Part 27-2: On-line partial discharge measurements on the stator winding insulation

IEC 60034-27-2:2023 deals with on-line PD measurements and provides a common basis with standardized procedures if possible for: - measuring techniques and instruments; - the arrangement of the installation; - normalization and sensitivity assessment; - measuring procedures; - noise reduction; - the documentation of results; - the interpretation of results; with respect to partial discharge on-line measurements on the stator winding insulation of non?converter driven rotating electrical machines with rated voltage of 3 kV and up. This document covers PD measuring systems and methods detecting electrical PD signals. The same measuring devices and procedures can also be used to detect electrical sparking and arcing phenomena.