ISO 15876-2:2017

ISO 15876-2:2017

January 2017
International standard Current

Plastics piping systems for hot and cold water installations - Polybutene (PB) - Part 2: Pipes

ISO 15876-2:2017 specifies the characteristics of pipes for polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15876‑1). The designation polybutene is used together with the abbreviation PB throughout this document. ISO 15876-2:2017 covers a range of service conditions (application classes), design pressures and pipe dimension classes. For values of TD, Tmax and Tmal in excess of those in ISO 15876‑1, this document does not apply. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It also specifies the test parameters for the test methods referred to in this document. In conjunction with the other parts of ISO 15876, this document is applicable to PB pipes, their joints and to joints with components of PB, other plastics and non-plastics materials intended to be used for hot and cold water installations. It is applicable to pipes with or without (a) barrier layer(s). NOTE 2 In the case of plastics pipes provided with a thin barrier layer, e.g. to prevent or greatly diminish the diffusion of gases and the transmission of light into or through the pipe wall, the design stress requirements are totally met by the base polymer (PB).

View the extract
Main informations

Collections

International ISO standards

Publication date

January 2017

Number of pages

16 p.

Reference

ISO 15876-2:2017

ICS Codes

23.040.20   Plastics pipes
91.140.60   Water supply systems

Print number

1
Sumary
Plastics piping systems for hot and cold water installations - Polybutene (PB) - Part 2: Pipes

ISO 15876-2:2017 specifies the characteristics of pipes for polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15876‑1).

The designation polybutene is used together with the abbreviation PB throughout this document.

ISO 15876-2:2017 covers a range of service conditions (application classes), design pressures and pipe dimension classes. For values of TD, Tmax and Tmal in excess of those in ISO 15876‑1, this document does not apply.

NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

It also specifies the test parameters for the test methods referred to in this document.

In conjunction with the other parts of ISO 15876, this document is applicable to PB pipes, their joints and to joints with components of PB, other plastics and non-plastics materials intended to be used for hot and cold water installations.

It is applicable to pipes with or without (a) barrier layer(s).

NOTE 2 In the case of plastics pipes provided with a thin barrier layer, e.g. to prevent or greatly diminish the diffusion of gases and the transmission of light into or through the pipe wall, the design stress requirements are totally met by the base polymer (PB).

Replaced standards (2)
ISO 15876-2:2003
December 2003
International standard Cancelled
Plastics piping systems for hot and cold water installations - Polybutylene (PB) - Part 2 : pipes

<p>ISO 15876-2:2003 specifies the characteristics of pipes made from polybutylene (PB) for piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) or for heating systems, under operating pressures and temperatures appropriate to the class of application.</p> <p>It covers a range of service conditions (application classes), design pressures and pipe dimension classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15876-1.</p> <p>It also specifies the test parameters for the test methods referred to in the standard.</p> <p>In conjunction with the other parts of ISO 15876, it is applicable to PB pipes and their joints, including joints with other PB components and components made of other plastics and non-plastics materials intended to be used for hot and cold water installations.</p> <p>It is applicable to pipes with or without (a) barrier layer(s).</p>

International standard Cancelled
Amendment 1 to standard ISO 15876-2:2003

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo