NF EN ISO 10304-1

NF EN ISO 10304-1

July 2009
Standard Current mandatory application standard

Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1 : determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate

ISO 10304-1:2007 specifies a method for the determination of dissolved bromide, chloride, fluoride, nitrate, nitrite, orthophosphate and sulfate in water, e.g. drinking water, ground water, surface water, waste water, leachates and marine water by liquid chromatography of ions. The lower limit of application is greater than or equal to 0,05 mg/l for bromide and for nitrite, and greater than or equal to 0,1 mg/l for chloride, fluoride, nitrate, orthophosphate, and sulfate. The lower limit of application depends on the matrix and the interferences encountered. The working range may be expanded to lower concentrations (e.g. greater than or equal to 0,01 mg/l) if an appropriate pre‑treatment of the sample (e.g. conditions for trace analyses, pre‑concentration technique) is applied, and/or if an UV detector (for bromide, nitrate and nitrite) is used.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

July 2009

Number of pages

26 p.

Reference

NF EN ISO 10304-1

ICS Codes

13.060.30   Sewage water
13.060.50   Examination of water for chemical substances

Classification index

T90-042-1

Print number

1 - 18/06/2009

International kinship

European kinship

EN ISO 10304-1:2009
Sumary
Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1 : determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate

ISO 10304-1:2007 specifies a method for the determination of dissolved bromide, chloride, fluoride, nitrate, nitrite, orthophosphate and sulfate in water, e.g. drinking water, ground water, surface water, waste water, leachates and marine water by liquid chromatography of ions.

The lower limit of application is greater than or equal to 0,05 mg/l for bromide and for nitrite, and greater than or equal to 0,1 mg/l for chloride, fluoride, nitrate, orthophosphate, and sulfate. The lower limit of application depends on the matrix and the interferences encountered.

The working range may be expanded to lower concentrations (e.g. greater than or equal to 0,01 mg/l) if an appropriate pre‑treatment of the sample (e.g. conditions for trace analyses, pre‑concentration technique) is applied, and/or if an UV detector (for bromide, nitrate and nitrite) is used.

Replaced standards (2)
NF EN ISO 10304-1
June 1995
Standard Cancelled
Water quality - Determination of dissolved fluoride, chloride, nitrite, orthophosphate, bromide, nitrate and sulfate ions, using liquid chromatography of ions - Part 1 : method for water with low contamination

NF EN ISO 10304-2
September 1996
Standard Cancelled
Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 2 : determination of bromide, chloride, nitrate, nitite, orthophosphate and sulfate in waste water

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Interférences
    2
  • 4 Principe
    2
  • 5 Réactifs
    3
  • 6 Appareillage
    5
  • 7 Échantillon et prétraitement de l'échantillon
    7
  • 8 Mode opératoire
    8
  • 9 Calcul
    9
  • 10 Expression des résultats
    9
  • 11 Rapport d'essai
    10
  • Annexe A (informative) Données de performance
    11
  • Annexe B (informative) Interférences vérifiées
    15
  • Bibliographie
    16
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ