NF EN ISO 140-4

NF EN ISO 140-4

December 1998
Standard Cancelled

Acoustics. Measurement of sound insulation in buildings and of building elements. Part 4 : field measurements of airborne sound insulation between rooms.

Le présent document indique les méthodes pour le mesurage de l'isolation acoustique des immeubles ainsi que la détermination de la protection assurée aux occupants de l'immeuble.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

December 1998

Number of pages

30 p.

Reference

NF EN ISO 140-4

ICS Codes

17.140.01   Acoustic measurements and noise abatement in general
91.120.20   Acoustics in building. Sound insulation

Classification index

S31-049-4

Print number

1 - 08/06/2005

International kinship

European kinship

EN ISO 140-4:1998
Sumary
Acoustics. Measurement of sound insulation in buildings and of building elements. Part 4 : field measurements of airborne sound insulation between rooms.

Le présent document indique les méthodes pour le mesurage de l'isolation acoustique des immeubles ainsi que la détermination de la protection assurée aux occupants de l'immeuble.
Replaced standards (1)
NF S31-054
August 1982
Standard Cancelled
Acoustics. Measurement of the acoustic insulation of buildings and building components. Investigatory method for the in situ measurement of airborne sound insulation between rooms.

Standard replaced by (1)
Standard Current
Acoustics - Field measurement of sound insulation in buildings and of building elements - Part 1 : airborne sound insulation

<p>ISO 16283-1:2014 specifies procedures to determine the airborne sound insulation between two rooms in a building using sound pressure measurements. These procedures are intended for room volumes in the range from 10 m<sup>3</sup> to 250 m<sup>3</sup> in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the airborne sound insulation in unfurnished or furnished rooms where the sound field may or may not approximate to a diffuse field. The measured airborne sound insulation is frequency-dependent and can be converted into a single number quantity to characterize the acoustic performance using the rating procedures in ISO 717‑1.</p>

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ