NF EN ISO 1452-4

NF EN ISO 1452-4

January 2010
Standard Current

Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4 : valves

ISO 1452-4:2009 specifies the characteristics of valves made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to. In conjunction with ISO 1452-1, ISO 1452-2, ISO 1452-3 and ISO 1452-5 it is applicable to PVC‑U valves with components of PVC-U, other plastics and non-plastics materials intended to be used for the following: - water mains and services buried in ground; - conveyance of water above ground for both outside and inside buildings; - buried and above-ground drainage and sewerage under pressure. It is applicable to valves in piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to valves for the conveyance of water and waste water up to and including 45 °C.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

January 2010

Number of pages

19 p.

Reference

NF EN ISO 1452-4

ICS Codes

23.040.20   Plastics pipes
23.040.45   Plastics fittings
91.140.60   Water supply systems
93.025   External water conveyance systems

Classification index

T54-016-4

Print number

1 - 18/01/2010

International kinship

European kinship

EN ISO 1452-4:2009
Sumary
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4 : valves

ISO 1452-4:2009 specifies the characteristics of valves made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to.

In conjunction with ISO 1452-1, ISO 1452-2, ISO 1452-3 and ISO 1452-5 it is applicable to PVC‑U valves with components of PVC-U, other plastics and non-plastics materials intended to be used for the following:

- water mains and services buried in ground;

- conveyance of water above ground for both outside and inside buildings;

- buried and above-ground drainage and sewerage under pressure.

It is applicable to valves in piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to valves for the conveyance of water and waste water up to and including 45 °C.

Replaced standards (2)
NF EN 1456-1
October 2001
Standard Cancelled
Plastics piping systems for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1 : specifications for piping components and the system

Le présent document spécifie les aspects généraux des systèmes de canalisations en poly(chlorure de vinyle) non plastifié (PVC-U) dans le domaine de l'assainissement enterré et aérien avec pression.

NF EN 1452-4
November 1999
Standard Cancelled
Plastics piping systems for water supply - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4 : valves and ancillary equipment

Le présent document précise les caractéristiques des robinets et des équipements auxiliaires en poly(chlorure de vinyle) non plastifié (PVC-U). Il est applicable aux systèmes de canalisations pour l'alimentation en eau destinée à la consommation humaine, jusqu'à 45°C inclus.

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    2
  • 3 Termes, définitions, symboles et abréviations
    3
  • 4 Matière
    3
  • 4.1 Corps de robinet
    3
  • 4.2 Masse volumique
    3
  • 4.3 Valeur MRS
    3
  • 4.4 Composants supplémentaires
    3
  • 5 Caractéristiques générales
    3
  • 5.1 Aspect
    3
  • 5.2 Couleur
    3
  • 5.3 Opacité
    3
  • 6 Caractéristiques géométriques
    4
  • 6.1 Mesurage de dimensions
    4
  • 6.2 Diamètres nominaux
    4
  • 6.3 Dimensions des robinets
    4
  • 7 Classification et conditions de service
    4
  • 7.1 Classification
    4
  • 7.2 Détermination de la pression de service admissible (PFA) pour l'eau jusqu'à 45 °C
    5
  • 8 Caractéristiques mécaniques
    5
  • 8.1 Résistance à la pression interne des corps de robinets
    5
  • 8.2 Essai d'écrasement
    5
  • 8.3 Durabilité
    5
  • 8.4 Propriétés fonctionnelles
    5
  • 9 Caractéristiques physiques
    6
  • 10 Caractéristiques chimiques
    7
  • 11 Bagues d'étanchéité
    7
  • 12 Adhésifs
    7
  • 13 Exigences de performance
    7
  • 14 Marquage
    7
  • 14.1 Généralités
    7
  • 14.2 Marquage minimum exigé
    7
  • 14.3 Marquage supplémentaire
    8
  • Annexe A (normative) Robinets en dimensions impériales (en pouces)
    9
  • Bibliographie
    11