NF EN ISO 5167-2

NF EN ISO 5167-2

June 2003
Standard Cancelled

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2 : orifice plates

ISO 5167-2:2003 specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit. It also provides background information for calculating the flow-rate and is applicable in conjunction with the requirements given in ISO 5167-1. ISO 5167-2:2003 is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as vena contracta and pipe tappings have been used with orifice plates but are not covered by ISO 5167-2:2003. ISO 5167-2:2003 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below 5 000.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

June 2003

Number of pages

58 p.

Reference

NF EN ISO 5167-2

ICS Codes

17.120.10   Flow in closed conduits

Classification index

X10-102-2

Print number

1 - 07/08/2003

International kinship

European kinship

EN ISO 5167-2:2003
Sumary
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2 : orifice plates

ISO 5167-2:2003 specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit.

It also provides background information for calculating the flow-rate and is applicable in conjunction with the requirements given in ISO 5167-1.

ISO 5167-2:2003 is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as vena contracta and pipe tappings have been used with orifice plates but are not covered by ISO 5167-2:2003.

ISO 5167-2:2003 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below 5 000.

Replaced standards (2)
NF EN ISO 5167-1
November 1995
Standard Cancelled
Measurement of fluid flow by means of pressure differential devices. Part 1 : orifice plates, nozzles and venturi tubes inserted in circular cross-section conduits running full.

NF EN ISO 5167-1/A1
October 1998
Standard Cancelled
Mesure de débit des fluides au moyen d'appareils déprimogènes - Partie 1 : diaphragmes, tuyères et tubes de venturi insérés dans des conduites en charge de section circulaire

Ce premier amendement à la norme ISO 5167-1:1991, permet un calcul amélioré du coefficient de décharge C. En outre, ce coefficient peut désormais être appliqué pour des nombres de Reynolds rapportés au diamètre de la conduite inférieures à 4 000 d'une part et d'autre part le rapport de diamètre beta = d/D doit être toujours supérieur ou égal à 0,10 et inférieur ou égal à 0,75.

Standard replaced by (1)
NF EN ISO 5167-2
June 2022
Standard Current
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates

<p>This document specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.</p> <p>This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1.</p> <p>This document is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with <em>D</em> and <em>D</em>/2 pressure tappings. Other pressure tappings such as “vena contracta” and pipe tappings are not covered by this document. This document is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow<sup>[</sup><sup>1</sup><sup>]</sup>. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or where the pipe Reynolds numbers are below 5 000.</p>

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • Domaine d'application
  • 2 Références normatives
  • 3 Termes, définitions et symboles
    2
  • 4 Principes de la méthode de mesurage et mode de calcul
    2
  • 5 Diaphragmes
    2
  • 5.1 Description
    3
  • 5.2 Prises de pression
    6
  • 5.3 Coefficients et incertitudes correspondantes des diaphragmes
    10
  • 5.4 Perte de pression, 0tu
    14
  • 6 Exigences d'installation
    16
  • 6.1 Généralités
    16
  • 6.2 Longueurs droites minimales d'amont et d'aval à installer entre différents accessoires et le diaphragme
    16
  • 6.3 Conditionneurs d'écoulement
    21
  • 6.4 Circularité et cylindricité de la conduite
    28
  • 6.5 Emplacement du diaphragme et des bagues porteuses
    29
  • 6.6 Mode de fixation et joints
    30
  • Annexe A (informative) Tableaux des coefficients de décharge et des coefficients de détente
    31
  • Annexe B (informative) Conditionneurs d'écoulement
    43
  • Bibliographie
    49
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ