NF ISO 15158
Corrosion of metals and alloys - Method of measuring the pitting potential for stainless steels by potentiodynamic control in sodium chloride solution
ISO 15158:2014 describes the procedure for determining the pitting potential for stainless steels (austenitic, ferritic/austenitic, ferritic, martensitic stainless steel) under potentiodynamic control. The principal advantage compared with other potentiostatic test methods is the rapidity of this test method, with which the pitting potential can be measured in a single potential scan. The pitting potential as determined by ISO 15158:2014 can be used as a relative index of performance. For example, one can compare the relative performances for different lots of stainless-steel grades and products. The test described in ISO 15158:2014 is not intended to determine the pitting potential at which actual pitting can occur under real service conditions, or not.
ISO 15158:2014 describes the procedure for determining the pitting potential for stainless steels (austenitic, ferritic/austenitic, ferritic, martensitic stainless steel) under potentiodynamic control.
The principal advantage compared with other potentiostatic test methods is the rapidity of this test method, with which the pitting potential can be measured in a single potential scan.
The pitting potential as determined by ISO 15158:2014 can be used as a relative index of performance. For example, one can compare the relative performances for different lots of stainless-steel grades and products. The test described in ISO 15158:2014 is not intended to determine the pitting potential at which actual pitting can occur under real service conditions, or not.
- Avant-proposiv
- Introductionv
-
1 Domaine d'application1
-
2 Principe1
-
3 Appareillage1
-
3.1 Potentiostat1
-
3.2 Appareil de mesure du potentiel d'électrode1
-
3.3 Appareils de mesure du courant1
-
3.4 Porte-éprouvette2
-
3.5 Cellule d'essai2
-
3.6 Électrode auxiliaire2
-
3.7 Electrode de référence3
-
4 Éprouvettes3
-
5 Mode opératoire3
-
5.1 Préparation des électrodes de référence3
-
5.2 Préparation de l'éprouvette3
-
5.3 Préparation de la solution4
-
5.4 Réalisation de l'essai4
-
5.5 Enregistrement4
-
5.6 Fin de l'essai5
-
6 Analyse statistique des données relatives au potentiel de piqûration5
-
7 Rapport d'essai6
- Annexe A (informative) Porte-éprouvette7
- Annexe B (informative) Exemple d'analyse statistique de données relatives au potentiel de piqûration11
- Bibliographie13