NF ISO 16000-14
Indoor air - Part 14 : determination of total (gas and particlephase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry
ISO 16000-14:2009 specifies extraction, clean-up, and analysis procedures for the determination of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) collected from indoor air on particle filters backed by polyurethane foam (PUF). The method incorporates specific analyses by high resolution gas chromatography combined with high resolution mass spectrometry (HRGC/HRMS). The method provides accurate quantitative data for tetra- to decachlorobiphenyls and tetra- to octachloro-dibenzo-p-dioxins/dibenzofurans (total concentrations for each isomeric series). It is capable of detecting 0,2 pg/m3 or lower concentrations of most PCBs and PCDFs/PCDDs with air sampling volumes up to 360 m3 or more in special cases. However, it may not be possible to detect all analytes at 0,2 pg/m3 or lower, especially at lower sampling volumes. Precision under normal conditions can be expected to be ±25 % or better and uncertainty ±50 % or better.
ISO 16000-14:2009 specifies extraction, clean-up, and analysis procedures for the determination of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) collected from indoor air on particle filters backed by polyurethane foam (PUF). The method incorporates specific analyses by high resolution gas chromatography combined with high resolution mass spectrometry (HRGC/HRMS).
The method provides accurate quantitative data for tetra- to decachlorobiphenyls and tetra- to octachloro-dibenzo-p-dioxins/dibenzofurans (total concentrations for each isomeric series). It is capable of detecting 0,2 pg/m3 or lower concentrations of most PCBs and PCDFs/PCDDs with air sampling volumes up to 360 m3 or more in special cases. However, it may not be possible to detect all analytes at 0,2 pg/m3 or lower, especially at lower sampling volumes.
Precision under normal conditions can be expected to be ±25 % or better and uncertainty ±50 % or better.
- Avant-proposiv
- Introductionvii
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Termes, définitions et termes abrégés2
-
4 Principe5
-
5 Appareillage et matériel de laboratoire5
-
6 Analyse8
-
7 Exigences minimales pour l'extraction et la purification16
-
8 Identification et quantification16
-
9 Critères d'assurance qualité applicables aux blancs de mode opératoire22
-
10 Récupération23
-
11 Calcul et présentation des résultats24
-
12 Mesures de sécurité25
-
13 Caractéristiques de performance25
-
14 Interférences28
- Annexe A (informative) Structure, toxicité et calcul des équivalents toxiques29
- Annexe B (informative) Exemple de purification des PCB/PCDD/PCDF et de séparation des PCB des PCDD/PCDF34
- Annexe C (informative) Analyse par GC/MS38
- Annexe D (informative) Masses des ions pour les PCDD/PCDF et les PCB44
- Annexe E (informative) Interférences46
- Annexe F (normative) Solutions d'étalonnage pour l'étalonnage du système GC/MS49
- Annexe G (informative) Écarts-types, limites de détection et concentrations dans l'air intérieur des PCB53
- Bibliographie55