NF ISO 5725-4

NF ISO 5725-4

September 2020
Standard Current

Accuracy (trueness and precision) of measurement methods and results - Part 4 : basic methods for the determination of the trueness of a standard measurement method

1.1 This document — specifies basic methods for estimating the bias of a measurement method and the laboratory bias when a measurement method is applied; — provides a practical approach of a basic method for routine use in estimating the bias of measurement methods and laboratory bias; — provides a brief guidance to all personnel concerned with designing, performing or analysing the results of the measurements for estimating bias. 1.2 It is concerned exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the measurement result, although the single value can be the outcome of a calculation from a set of observations. 1.3 This document applies when the measurement method has been standardized and all measurements are carried out according to that measurement method. NOTE In ISO/IEC Guide 99:2007(VIM), "measurement procedure" (2.6) is an analogous term related to the term "measurement method" used in this document. 1.4 This document applies only if an accepted reference value can be established to substitute the true value by using the value, for example: — of a suitable reference material; — of a suitable measurement standard; — referring to a suitable measurement method; — of a suitable prepared known sample. 1.5 This document applies only to the cases where it is sufficient to estimate bias on one property at a time. It is not applicable if the bias in the measurement of one property is affected by the level of any other property (i.e. it does not consider interferences by any influencing quantity). Comparison of the trueness of two-measurement methods is considered in ISO 5725-6.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

September 2020

Number of pages

32 p.

Reference

NF ISO 5725-4

ICS Codes

03.120.30   Application of statistical methods
17.020   Metrology and measurement in general

Classification index

X06-041-4

Print number

1

International kinship

Sumary
Accuracy (trueness and precision) of measurement methods and results - Part 4 : basic methods for the determination of the trueness of a standard measurement method

1.1 This document

— specifies basic methods for estimating the bias of a measurement method and the laboratory bias when a measurement method is applied;

— provides a practical approach of a basic method for routine use in estimating the bias of measurement methods and laboratory bias;

— provides a brief guidance to all personnel concerned with designing, performing or analysing the results of the measurements for estimating bias.

1.2 It is concerned exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the measurement result, although the single value can be the outcome of a calculation from a set of observations.

1.3 This document applies when the measurement method has been standardized and all measurements are carried out according to that measurement method.

NOTE In ISO/IEC Guide 99:2007(VIM), "measurement procedure" (2.6) is an analogous term related to the term "measurement method" used in this document.

1.4 This document applies only if an accepted reference value can be established to substitute the true value by using the value, for example:

— of a suitable reference material;

— of a suitable measurement standard;

— referring to a suitable measurement method;

— of a suitable prepared known sample.

1.5 This document applies only to the cases where it is sufficient to estimate bias on one property at a time. It is not applicable if the bias in the measurement of one property is affected by the level of any other property (i.e. it does not consider interferences by any influencing quantity). Comparison of the trueness of two-measurement methods is considered in ISO 5725-6.

Replaced standards (1)
NF ISO 5725-4
December 1994
Standard Cancelled
Application of statistics. Accuracy (trueness and precision) of measurement methods and results. Part 4 : basic methods for the determination of the trueness of a standard measurement method.

Table of contents
View the extract
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Symboles
  • 5 Détermination du biais d'une méthode de mesure normalisée par une expérience interlaboratoires
  • 6 Détermination du biais de laboratoire d'un laboratoire utilisant une méthode de mesure normalisée
  • 7 Rapport destiné au panel d'experts et décisions du panel
  • Annexe A Établissement des formules
  • Annexe B Exemple d'une expérience d'exactitude
  • Bibliographie
What is the Redline format?
The Redline + service - standards comparator allows you to easily and simply identify major changes between the current standard and its last canceled version.

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.

For an overview of the service, click on View a standard in redline format
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ