ASTM D4729-19

ASTM D4729-19

juin 2019
Norme En vigueur

Standard Test Method for In Situ Stress and Modulus of Deformation Using the Flat Jack Method

Information importante
Pour la consultation de ce document, l'installation du plug in FileOpen est nécessaire.
la consultation du document est disponible uniquement en version PDF avec une utilisation monoposte et l'impression n'est pas autorisée.
Si ce n'est pas déjà fait, téléchargez le plug-in ICI
Consultez ICI nos prérequis.
Informations générales

Collections

Normes américaines ASTM

Date de publication

juin 2019

Nombre de pages

10 p.

Référence

ASTM D4729-19

Indice de classement

D4729-19
Normes remplacées (1)
ASTM D4729-08
juillet 2008
Norme Annulée
Standard Test Method for In Situ Stress and Modulus of Deformation Using Flatjack Method (Withdrawn 2017)

1.1 The flatjack test measures stress at a rock surface. The modulus of deformation and the long-term deformational properties (creep) may also be evaluated. 1.2 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026. 1.2.1 The method used to specifiy how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope. 1.3 Limitation-The flatjack test measures the average stress normal to the surface of the test chamber. Undisturbed stress levels must be determined by theoretical interpretations of these data. 1.4 Assumptions and Factors Influencing the Data: 1.4.1 The stress relief is assumed to be an elastic, reversible process. In nonhomogeneous or highly fractured materials, this may not be completely true. 1.4.2 The equations assume that the rock mass is isotropic and homogeneous. Anisotropic effects may be estimated by testing in different orientations. 1.4.3 The flatjack is assumed to be 100 % efficient. The design and size requirements of 7.1 were determined to satisfy this requirement to within a few percent. 1.4.4 The jack is assumed to be aligned with the principal stresses on the surface of the opening. Shear stresses are not canceled by jack pressure. Orientating the tests in three directions in each plane tested prevents the misalignment from being excessive for at least one of the tests. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement

Je découvre COBAZ