ASTM E580/E580M-11b

ASTM E580/E580M-11b

novembre 2011
Norme Annulée

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions

This practice covers acoustical ceiling suspension systems and their additional requirements in buildings in International Building Code Seismic Design Categories C, D, E, and F. The application of this practice is to be determined by local authorities. Current seismic maps published by recognized authorities such as the International Building Code, the American Society for Civil Engineers, as well as related material such as the United States Geological Survey Open File 82-1033 and MS-812 Seismicity Maps, should be consulted. This practice is not intended to stifle research and development of new products or methods which may simplify the application method specified herein. A variation, however, must be substantiated by verifiable engineering data or dynamic testing. A ceiling area of 144 ft2[13m2] or less, surrounded by walls that connect directly to the structure above shall be exempt from this practice as are gypsum board ceilings on one level surrounded by walls connected directly to the structure above.

Information importante
Pour la consultation de ce document, l'installation du plug in FileOpen est nécessaire.
la consultation du document est disponible uniquement en version PDF avec une utilisation monoposte et l'impression n'est pas autorisée.
Si ce n'est pas déjà fait, téléchargez le plug-in ICI
Consultez ICI nos prérequis.
Informations générales

Collections

Normes américaines ASTM

Date de publication

novembre 2011

Nombre de pages

10 p.

Référence

ASTM E580/E580M-11b

Indice de classement

E0580_E0580M-11B
Résumé
Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions

This practice covers acoustical ceiling suspension systems and their additional requirements in buildings in International Building Code Seismic Design Categories C, D, E, and F. The application of this practice is to be determined by local authorities. Current seismic maps published by recognized authorities such as the International Building Code, the American Society for Civil Engineers, as well as related material such as the United States Geological Survey Open File 82-1033 and MS-812 Seismicity Maps, should be consulted. This practice is not intended to stifle research and development of new products or methods which may simplify the application method specified herein. A variation, however, must be substantiated by verifiable engineering data or dynamic testing. A ceiling area of 144 ft2[13m2] or less, surrounded by walls that connect directly to the structure above shall be exempt from this practice as are gypsum board ceilings on one level surrounded by walls connected directly to the structure above.

Qu'est-ce que le format Redline ?
Le service Redline+ - comparateur de normes vous permet d’identifier facilement et simplement les changements majeurs entre la norme en vigueur et sa dernière version annulée.

D’un simple coup d’oeil, vous pourrez identifier les ajouts, suppressions ou modifications à un texte, tableau, figure et formule.
D’un simple coup d’oeil, vous pourrez identifier les ajouts, suppressions ou modifications à un texte, tableau, figure et formule

Le service Redlines+ vous est proposé sur la collection des normes françaises en vigueur, en langue Française et au format HTML et PDF.

Pour un aperçu du service, veuillez cliquer sur Visualiser une norme au format redline
Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement

Je découvre COBAZ