IEC 61000-2-9:2025

IEC 61000-2-9:2025

mai 2025
Norme internationale En vigueur

Electromagnetic compatibility (EMC) - Part 2-9: Environment - Description of HEMP environment - Radiated disturbance

IEC 61000-2-9: 2025 defines the high-altitude electromagnetic pulse (HEMP) environment that is one of the consequences of a high-altitude nuclear explosion. There are two cases of nuclear detonations:- high-altitude nuclear explosions;- low-altitude nuclear explosions.For civil systems, the most important case is the high-altitude nuclear explosion. In this case, the other effects of the nuclear explosion such as blast, ground shock, thermal and nuclear ionizing radiation are not present at the ground level. However, the electromagnetic pulse associated with the explosion can cause disruption of, and damage to, communications, electronic systems, electric power systems and other portions of the commercial critical infrastructures, thereby upsetting the stability of modern society. The object of this document is to establish a common reference for the HEMP environment in order to select realistic stresses to apply to victim equipment for evaluating their performance and in order to develop protection methods to minimize the impacts of the HEMP. This second edition cancels and replaces the first edition published in 1996. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) updating the document to provide new information on the variation of the early-time HEMP on the earth's surface and to provide new information on the late-time HEMP;b) adding a new informative Annex A which provides details concerning the development of the early- and late-time standard waveforms in the main body, an explanation of the advantages and disadvantages for the use of the double exponential waveform, and an explanation of the far field region for the early-time HEMP.IEC 61000-2-9: 2025 has the status of a basic EMC publication in accordance with IEC Guide 107.

Informations générales

Collections

Normes internationales IEC

Date de publication

mai 2025

Nombre de pages

41 p.

Référence

IEC 61000-2-9:2025

Numéro de tirage

2
Résumé
Electromagnetic compatibility (EMC) - Part 2-9: Environment - Description of HEMP environment - Radiated disturbance

IEC 61000-2-9: 2025 defines the high-altitude electromagnetic pulse (HEMP) environment that is one of the consequences of a high-altitude nuclear explosion. There are two cases of nuclear detonations:
- high-altitude nuclear explosions;
- low-altitude nuclear explosions.
For civil systems, the most important case is the high-altitude nuclear explosion. In this case, the other effects of the nuclear explosion such as blast, ground shock, thermal and nuclear ionizing radiation are not present at the ground level. However, the electromagnetic pulse associated with the explosion can cause disruption of, and damage to, communications, electronic systems, electric power systems and other portions of the commercial critical infrastructures, thereby upsetting the stability of modern society. The object of this document is to establish a common reference for the HEMP environment in order to select realistic stresses to apply to victim equipment for evaluating their performance and in order to develop protection methods to minimize the impacts of the HEMP. This second edition cancels and replaces the first edition published in 1996. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) updating the document to provide new information on the variation of the early-time HEMP on the earth's surface and to provide new information on the late-time HEMP;
b) adding a new informative Annex A which provides details concerning the development of the early- and late-time standard waveforms in the main body, an explanation of the advantages and disadvantages for the use of the double exponential waveform, and an explanation of the far field region for the early-time HEMP.
IEC 61000-2-9: 2025 has the status of a basic EMC publication in accordance with IEC Guide 107.
Normes remplacées (1)
IEC 61000-2-9:1996
février 1996
Norme internationale Annulée
Compatibilité électromagnétique (CEM) - Partie 2: Environnement - Section 9: Description de l'environnement IEMN-HA - Perturbations radiantes. Publication fondamentale en CEM

La présente section de la CEI 61000-2 définit l'environnement IEMN-HA (impulsion électromagnétique à haute altitude) consécutif à une explosion nucléaire à haute altitude. Deux cas sont généralement étudiés; - les explosions nucléaires à haute altitude; - les explosions nucléaires à basse altitude. Pour les systèmes civils, le cas le plus important est celui des explosions nucléaires à haute altitude. Dans ce cas, les autres effets de l'explosion nucléaire (souffle, onde de choc au sol, rayonnements thermiques et ionisants nucléaires) n'existent pas au niveau du sol. Les impulsions électromagnétiques liées à l'explosion peuvent cependant perturber et endommager les systèmes de communication, les systèmes électroniques et le réseau électrique, mettant par là même en péril l'équilibre de la sociéé moderne. Le but de cette norme est d'établir une référence commune sur l'environnement IEMN-HA permettant de définir des contraintes réalistes à appliquer afin d'évaluer les performances des équipements atteints.

ZOOM SUR... le service Exigences
Pour respecter une norme, vous avez besoin de comprendre rapidement ses enjeux afin de déterminer son impact sur votre activité.

Le service Exigences vous aide à repérer rapidement au sein du texte normatif :
- les clauses impératives à satisfaire,
- les clauses non indispensables mais utiles à connaitre, telles que les permissions et les recommandations.

L’identification de ces types de clauses repose sur le document « Directives ISO/IEC, Partie 2 - Principes et règles de structure et de rédaction des documents ISO » ainsi que sur une liste de formes verbales constamment enrichie.

Avec Exigences, accédez rapidement à l’essentiel du texte normatif !

Avec Exigences, accédez rapidement à l'essentiel du texte normatif !
Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement