IEC/IEEE 60076-16:2018
Power transformers - Part 16: Transformers for wind turbine applications
IEC/IEEE 60076-16:2018 is also available as IEC/IEEE 60076-16:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC/IEEE 60076-16:2018 applies to dry-type and liquid-immersed transformers for wind turbine step-up application having a winding with highest voltage for equipment up to and including 72,5 kV. This document applies to the transformer used to connect the wind turbine generator to the wind farm power collection system or adjacent distribution network and not the transformer used to connect several wind turbines to a distribution or transmission network. Transformers covered by this document comply with the relevant requirements prescribed in the IEC 60076 standards or IEEE C57 standards. This second edition of IEC/IEEE 60076-16 cancels and replaces IEC 60076-16:2011, and constitutes a technical revision. The main changes with respect to the previous edition are as follows:1) relationship between transformer rated power and the output current from the associated generator is introduced;2) thermal correction of the effective cooling medium has been introduced;3) testing regime has been strengthened to ensure transformers are suitable for the harsh electrical environment to which they are subjected.Keywords: transformers for wind turbine applications
IEC/IEEE 60076-16:2018 is also available as IEC/IEEE 60076-16:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC/IEEE 60076-16:2018 applies to dry-type and liquid-immersed transformers for wind turbine step-up application having a winding with highest voltage for equipment up to and including 72,5 kV. This document applies to the transformer used to connect the wind turbine generator to the wind farm power collection system or adjacent distribution network and not the transformer used to connect several wind turbines to a distribution or transmission network. Transformers covered by this document comply with the relevant requirements prescribed in the IEC 60076 standards or IEEE C57 standards. This second edition of IEC/IEEE 60076-16 cancels and replaces IEC 60076-16:2011, and constitutes a technical revision. The main changes with respect to the previous edition are as follows:
1) relationship between transformer rated power and the output current from the associated generator is introduced;
2) thermal correction of the effective cooling medium has been introduced;
3) testing regime has been strengthened to ensure transformers are suitable for the harsh electrical environment to which they are subjected.
Keywords: transformers for wind turbine applications
Le service Exigences vous aide à repérer rapidement au sein du texte normatif :
- les clauses impératives à satisfaire,
- les clauses non indispensables mais utiles à connaitre, telles que les permissions et les recommandations.
L’identification de ces types de clauses repose sur le document « Directives ISO/IEC, Partie 2 - Principes et règles de structure et de rédaction des documents ISO » ainsi que sur une liste de formes verbales constamment enrichie.
Avec Exigences, accédez rapidement à l’essentiel du texte normatif !

D’un simple coup d’oeil, vous pourrez identifier les ajouts, suppressions ou modifications à un texte, tableau, figure et formule.

Le service Redlines+ vous est proposé sur la collection des normes françaises en vigueur, en langue Française et au format HTML et PDF.
Pour un aperçu du service, veuillez cliquer sur Visualiser une norme au format redline
COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.
Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !
Demandez votre démo live gratuite, sans engagement
Je découvre COBAZ