ISO 4443:2022
Cryolite primarily used for the production of aluminium - Determination of elements - Wavelength-dispersive X-ray fluorescence spectrometric method using pressed powder tablets
This document specifies a wavelength-dispersive X-ray fluorescence spectrometric (XRF) method for the determination of cryolite (Na3AlF6) from the content of fluorine to the content of trace elements. The calibration reference materials are not specified in this method. The method is applicable to cryolite, which is primarily used for the production of aluminium. Annex A provides conversion factors for converting elements to compounds. The validity and precision of test results for concentrations outside these ranges has not been determined. The concentration range of fluorine (given as F) is from 510 g/kg to 560 g/kg. The concentration range of aluminium (given as Al) is from 120 g/kg to 150 g/kg. The concentration range of sodium (given as Na) is from 270 g/kg to 330 g/kg. The concentration range of silicon (given as SiO2) is from the lowest limit of detection (LLD) to 4,0 g/kg. The concentration range of iron (given as Fe2O3) is from LLD to 0,37 g/kg. The concentration range of sulfur (given as SO4) is from LLD to 5,0 g/kg. The concentration range of phosphorus (given as P2O5) is from LLD to 0,40 g/kg. The concentration range of calcium (given as CaO) is from LLD to 0,80 g/kg.
This document specifies a wavelength-dispersive X-ray fluorescence spectrometric (XRF) method for the determination of cryolite (Na3AlF6) from the content of fluorine to the content of trace elements. The calibration reference materials are not specified in this method.
The method is applicable to cryolite, which is primarily used for the production of aluminium. Annex A provides conversion factors for converting elements to compounds. The validity and precision of test results for concentrations outside these ranges has not been determined.
The concentration range of fluorine (given as F) is from 510 g/kg to 560 g/kg. The concentration range of aluminium (given as Al) is from 120 g/kg to 150 g/kg. The concentration range of sodium (given as Na) is from 270 g/kg to 330 g/kg. The concentration range of silicon (given as SiO2) is from the lowest limit of detection (LLD) to 4,0 g/kg. The concentration range of iron (given as Fe2O3) is from LLD to 0,37 g/kg. The concentration range of sulfur (given as SO4) is from LLD to 5,0 g/kg. The concentration range of phosphorus (given as P2O5) is from LLD to 0,40 g/kg. The concentration range of calcium (given as CaO) is from LLD to 0,80 g/kg.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ