NF ISO 10473

NF ISO 10473

August 2000
Standard Current

Ambient air - Measurement of the mass of particulate matter on a filter medium - Beta-ray absorption method

This International Standard describes a method for the measurement of the mass of particulate matter in ambient air and is based on the absorption of beta rays by the particulate matter. This method applies to the determination of concentrations ranging from a few micrograms per cubic metre to a few milligrams per cubic metre contained in the atmospheres of urban, rural or industrial areas. The lower mass detection limit of the method is usually 15 μg to 30 μg of deposited mass per square centimetre of surface area, S, of the filter. This means, for a sampling time t of 3 h and a flowrate q of 1 m3/h, that the concentration detection limit ranges between 5 μg/m3 and 10 μg/m3, computed as follows: Sampling techniques are not included in the scope of this International Standard. NOTE The concentration of particulate matter is calculated by dividing the mass deposited on a filter tape or individual filter, by the known volume of air sampled. However, concentration is dependent on the sampling technique used, for example, the design of the sampling inlet. Normally, for ambient-air particle sampling, large particles are filtered out by means of a sizeselective inlet (for example cascade impactor or cyclone filtration). The particle size limit is defined by the characteristics of the sampling head.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

August 2000

Number of pages

16 p.

Reference

NF ISO 10473

ICS Codes

13.040.20   Ambient atmospheres

Classification index

X43-040

Print number

1 - 02/06/2005

International kinship

Sumary
Ambient air - Measurement of the mass of particulate matter on a filter medium - Beta-ray absorption method

This International Standard describes a method for the measurement of the mass of particulate matter in ambient

air and is based on the absorption of beta rays by the particulate matter.

This method applies to the determination of concentrations ranging from a few micrograms per cubic metre to a few

milligrams per cubic metre contained in the atmospheres of urban, rural or industrial areas.

The lower mass detection limit of the method is usually 15 μg to 30 μg of deposited mass per square centimetre of

surface area, S, of the filter. This means, for a sampling time t of 3 h and a flowrate q of 1 m3/h, that the

concentration detection limit ranges between 5 μg/m3 and 10 μg/m3, computed as follows:

Sampling techniques are not included in the scope of this International Standard.

NOTE The concentration of particulate matter is calculated by dividing the mass deposited on a filter tape or individual

filter, by the known volume of air sampled. However, concentration is dependent on the sampling technique used, for example,

the design of the sampling inlet. Normally, for ambient-air particle sampling, large particles are filtered out by means of a sizeselective

inlet (for example cascade impactor or cyclone filtration). The particle size limit is defined by the characteristics of the

sampling head.

Table of contents
View the extract
  • Avant-propos
    IV
  • 1
    Domaine d'application 1
  • 2
    Terme et définition 1
  • 3
    Principe 1
  • 3.1
    Description 1
  • 3.2
    Limites 2
  • 4
    Appareillage 3
  • 4.1
    Appareillage à échantillonnage et analyse séquentiels ou simultanés 3
  • 4.2
    Appareillage à échantillonnage et analyse dissociés 7
  • 5
    Étalonnage de la jauge bêta 7
  • 5.1
    Mise à zéro et variabilité du zéro 7
  • 5.2
    Étalonnage 9
  • 6
    Mode opératoire 9
  • 6.1
    Durée de l'échantillonnage 9
  • 6.2
    Appareillage automatique à échantillonnage et analyse séquentiels ou simultanés 9
  • 6.3
    Appareillage automatique à échantillonnage et analyse dissociés 11
  • 7
    Expression des résultats 11
  • 8
    Rapport d'essai 11
  • Bibliographie
    12
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ