A la demande de l’éditeur, la consultation du document est disponible uniquement en version PDF avec une utilisation monoposte et l'impression n'est pas autorisée. Si vous n’êtes pas la personne destinée à utiliser ce document, ne pas le télécharger sur votre poste, sinon cette dernière ne pourra pas l’ouvrir.
ASTM A795/A795M-21
Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use
This specification covers black and hot-dipped zinc-coated (galvanized) welded and seamless steel pipe for fire protection use. The pipe may be bent, but it is not intended for bending made at ambient temperature wherein the inside diameter of the bend is less than twelve times the outside diameter of the pipe being bent. The steel shall conform to the required chemical composition. Each length of pipe shall be subjected to a hydrostatic test without leakage through the pipe wall. As an alternative to the hydrostatic test, and when accepted by the purchaser, each pipe shall be tested with a non-destructive electrical method. Finally, flattening test shall be performed on the pipe in accordance with, electric-resistance-welded pipe, and furnace-welded pipe.
A la demande de l’éditeur, la consultation du document est disponible uniquement en version PDF avec une utilisation monoposte et l'impression n'est pas autorisée. Si vous n’êtes pas la personne destinée à utiliser ce document, ne pas le télécharger sur votre poste, sinon cette dernière ne pourra pas l’ouvrir.
Collections
Date de publication
Nombre de pages
Référence
Indice de classement
This specification covers black and hot-dipped zinc-coated (galvanized) welded and seamless steel pipe for fire protection use. The pipe may be bent, but it is not intended for bending made at ambient temperature wherein the inside diameter of the bend is less than twelve times the outside diameter of the pipe being bent. The steel shall conform to the required chemical composition. Each length of pipe shall be subjected to a hydrostatic test without leakage through the pipe wall. As an alternative to the hydrostatic test, and when accepted by the purchaser, each pipe shall be tested with a non-destructive electrical method. Finally, flattening test shall be performed on the pipe in accordance with, electric-resistance-welded pipe, and furnace-welded pipe.
This specification covers black and hot-dipped zinc-coated (galvanized) welded and seamless steel pipe for fire protection use. The pipe may be bent, but it is not intended for bending made at ambient temperature wherein the inside diameter of the bend is less than twelve times the outside diameter of the pipe being bent. The steel shall conform to the required chemical composition. Each length of pipe shall be subjected to a hydrostatic test without leakage through the pipe wall. As an alternative to the hydrostatic test, and when accepted by the purchaser, each pipe shall be tested with a non-destructive electrical method. Finally, flattening test shall be performed on the pipe in accordance with, electric-resistance-welded pipe, and furnace-welded pipe.
D’un simple coup d’oeil, vous pourrez identifier les ajouts, suppressions ou modifications à un texte, tableau, figure et formule.

Le service Redlines+ vous est proposé sur la collection des normes françaises en vigueur, en langue Française et au format HTML et PDF.
Pour un aperçu du service, veuillez cliquer sur Visualiser une norme au format redline
COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.
Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !
Demandez votre démo live gratuite, sans engagement
Je découvre COBAZ