ASTM C387/C387M-06a

ASTM C387/C387M-06a

juillet 2006
Norme Annulée

Standard Specification for Packaged, Dry, Combined Materials for Mortar and Concrete

1.1 This specification covers the production, properties, packaging, and testing of packaged, dry, combined materials for concrete and mortars. The types of concrete and mortar covered are described in the following paragraphs in this section. Some of the mixtures covered by this specification may not be available in some areas. 1.1.1 High-Early Strength ConcreteFor concrete building and repair jobs requiring a more rapid strength development such as required for the earlier removal of forms. 1.1.2 Normal Strength ConcreteNormal Weight ConcreteFor general concrete building and repair jobs where thicknesses exceed 50 mm [2 in.]. Typical uses include building or repairing sidewalks, patios, steps, footings, and for setting posts. Lightweight Concrete Using Normal Weight SandFor concrete building and repair jobs where lower concrete weights are desirable. These mixtures will produce concrete which is about 15 to 25 % lighter in weight than normal weight concrete. Lightweight ConcreteFor concrete building and repair jobs where the lightest concrete weight is desirable. These mixtures will produce concrete which is about 25 to 35 % lighter in weight than normal weight concrete. 1.1.3 High-Strength MortarFor general concrete work requiring thicknesses of less than 50 mm [2 in.] or where a high-strength grout mixture is required. Typical uses include topping, patching, and stuccoing. Often referred to as sand mix. 1.1.4 Mortars for Unit MasonryFor laying brick, block, and stone, and for masonry repairs. The following three types of masonry mortar are covered: Type NFor general masonry work requiring normal mortar properties. Type SFor use where a higher strength masonry mortar is required. Type MFor use where the highest strength masonry mortar is required. 1.2 The values stated in either SI or inch-pound units shall be regarded separately as standard. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 The following safety hazards caveat pertains only to the test method portion of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Information importante
Pour la consultation de ce document, l'installation du plug in FileOpen est nécessaire.
A la demande de l’éditeur, la consultation du document est disponible uniquement en version PDF avec une utilisation monoposte et l'impression n'est pas autorisée. Si vous n’êtes pas la personne destinée à utiliser ce document, ne pas le télécharger sur votre poste, sinon cette dernière ne pourra pas l’ouvrir.
En cas de problème, merci de cliquer ici pour contacter le support client
Si ce n'est pas déjà fait, téléchargez le plug-in ICI
Consultez ICI nos prérequis.
Informations générales

Collections

Normes américaines ASTM

Date de publication

juillet 2006

Référence

ASTM C387/C387M-06a
Résumé
Standard Specification for Packaged, Dry, Combined Materials for Mortar and Concrete

1.1 This specification covers the production, properties, packaging, and testing of packaged, dry, combined materials for concrete and mortars. The types of concrete and mortar covered are described in the following paragraphs in this section. Some of the mixtures covered by this specification may not be available in some areas. 1.1.1 High-Early Strength ConcreteFor concrete building and repair jobs requiring a more rapid strength development such as required for the earlier removal of forms. 1.1.2 Normal Strength ConcreteNormal Weight ConcreteFor general concrete building and repair jobs where thicknesses exceed 50 mm [2 in.]. Typical uses include building or repairing sidewalks, patios, steps, footings, and for setting posts. Lightweight Concrete Using Normal Weight SandFor concrete building and repair jobs where lower concrete weights are desirable. These mixtures will produce concrete which is about 15 to 25 % lighter in weight than normal weight concrete. Lightweight ConcreteFor concrete building and repair jobs where the lightest concrete weight is desirable. These mixtures will produce concrete which is about 25 to 35 % lighter in weight than normal weight concrete. 1.1.3 High-Strength MortarFor general concrete work requiring thicknesses of less than 50 mm [2 in.] or where a high-strength grout mixture is required. Typical uses include topping, patching, and stuccoing. Often referred to as sand mix. 1.1.4 Mortars for Unit MasonryFor laying brick, block, and stone, and for masonry repairs. The following three types of masonry mortar are covered: Type NFor general masonry work requiring normal mortar properties. Type SFor use where a higher strength masonry mortar is required. Type MFor use where the highest strength masonry mortar is required. 1.2 The values stated in either SI or inch-pound units shall be regarded separately as standard. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.3 The following safety hazards caveat pertains only to the test method portion of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Normes remplacées (1)
ASTM C387-06
janvier 2006
Norme Annulée
Standard Specification for Packaged, Dry, Combined Materials for Mortar and Concrete

1.1 This specification covers the production, properties, packaging, and testing of packaged, dry, combined materials for concrete and mortars. The types of concrete and mortar covered are described in the following paragraphs in this section. Some of the mixtures covered by this specification may not be available in some areas.1.1.1 High-Early Strength Concrete-For concrete building and repair jobs requiring a more rapid strength development such as required for the earlier removal of forms.1.1.2 Normal Strength Concrete: Normal Weight ConcreteFor general concrete building and repair jobs where thicknesses exceed 50 mm (2-in.). Typical uses include building or repairing sidewalks, patios, steps, footings, and for setting posts.1.1.2.2 Lightweight Concrete Using Normal Weight Sand-For concrete building and repair jobs where lower concrete weights are desirable. These mixtures will produce concrete which is about 25 to 35 % lighter in weight than normal weight concrete.1.1.2.3 Lightweight Concrete-For concrete building and repair jobs where the lightest concrete weight is desirable. These mixtures will produce concrete which is about 25 to 35 % lighter in weight than normal weight concrete.1.1.3 High-Strength Mortar-For general concrete work requiring thicknesses of less than 50 mm (2-in.) or where a high-strength grout mixture is required. Typical uses include topping, patching, and stuccoing. Often referred to as sand mix.1.1.4 Mortars for Unit Masonry-For laying brick, block, and stone, and for masonry repairs. The following three types of masonry mortar are covered:1.1.4.1 Type N-For general masonry work requiring normal mortar properties.1.1.4.2 Type S-For use where a higher strength masonry mortar is required.1.1.4.3 Type M-For use where the highest strength masonry mortar is required.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.1.2.1 Values in SI units shall be obtained by measurement in SI units or by appropriate conversion of measurements made in other units, using the Rules for Conversion and Rounding given in IEEE/ASTM SI 10.1.3 The following safety hazards caveat pertains only to the test method portion of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Norme remplacée par (1)
ASTM C387/C387M-08
décembre 2008
Norme Annulée
Standard Specification for Packaged, Dry, Combined Materials for Mortar and Concrete

This specification covers the production, properties, packaging, and testing of packaged, dry, combined materials for concrete and mortars. Concrete mixtures covered by this specification includes high-early strength concrete, normal strength concrete, normal weight concrete, high-strength mortar, and mortars for unit masonry. The purchaser shall specify the material desired as concrete, high strength mortar, or mortar for use with unit masonry, and the respective physical requirements. Materials used as ingredients in packaged, dry, combined materials for mortar and concrete shall be composed of aggregates, air-entraining admixtures, blended cement, chemical admixtures, fly ash, ground granulated blast-furnace slag, hydrated lime, latex and powder polymer modifiers, masonry cement, mortar cement, Portland cement, and silica fume. All aggregates shall be dried, without disintegration, to specific moisture content The proportions of cementitious material and aggregate shall be such that the strength requirements will be met. Packaged, dry, combined materials for concrete, high strength mortar and mortar for use with unit masonry shall conform to the respective compressive strength requirements. Scales conforming to the standards will be used for sampling concretes from a single batch using a sufficient quantity. A slump test will be performed to check if additional water is required. In sampling mortar, the contents of an entire package of dry, combined material for mortar for unit masonry or for concrete mortar shall be used. Mortar mixing equipment, which must be provided with a bowl positioning adapter, shall be used to ensure clearance for the largest size aggregate in the mix being tested. The specification includes the following testing methods for mortar: compressive strength, density and yield, air content, and water retention.

Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement

Je découvre COBAZ