Standard Test Method for Wavelength Accuracy and Spectral Bandwidth of Fluorescence Spectrometers

This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier tube detection. The method can be applied to instruments that use multi-element detectors, such as diode arrays, but results must be interpreted carefully. Atomic lines between 250 nm and 1000 nm are used in the method. The difference between the apparent wavelength and the known wavelength for a series of atomic emission lines is used as a test for wavelength accuracy. The apparent width of some of these lines is used as a test for spectral bandwidth.

Information importante
Pour la consultation de ce document, l'installation du plug in FileOpen est nécessaire.
A la demande de l’éditeur, la consultation du document est disponible uniquement en version PDF avec une utilisation monoposte et l'impression n'est pas autorisée. Si vous n’êtes pas la personne destinée à utiliser ce document, ne pas le télécharger sur votre poste, sinon cette dernière ne pourra pas l’ouvrir.
En cas de problème, merci de cliquer ici pour contacter le support client
Si ce n'est pas déjà fait, téléchargez le plug-in ICI
Consultez ICI nos prérequis.
Informations générales

Collections

Normes américaines ASTM

Date de publication

janvier 2023

Nombre de pages

3 p.

Référence

ASTM E388-04(2023)

Indice de classement

E0388-04R23
Résumé
Standard Test Method for Wavelength Accuracy and Spectral Bandwidth of Fluorescence Spectrometers

This test method covers the testing of the spectral bandwidth and wavelength accuracy of fluorescence spectrometers that use a monochromator for emission wavelength selection and photomultiplier tube detection. The method can be applied to instruments that use multi-element detectors, such as diode arrays, but results must be interpreted carefully. Atomic lines between 250 nm and 1000 nm are used in the method. The difference between the apparent wavelength and the known wavelength for a series of atomic emission lines is used as a test for wavelength accuracy. The apparent width of some of these lines is used as a test for spectral bandwidth.