Standard Test Method for Arrhenius Kinetic Constants for Thermally Unstable Materials

1.1 This method covers the determination of the overall kinetic parameters for exothermic reactions.1.2 The kinetic parameters are obtained from differential scanning calorimetry (DSC) curves (see Section 3).1.3 This technique is applicable to reactions whose behavior can be described by the Arrhenius equation and the general rate law.1.4 Limitations-There are cases where this technique is not applicable. Limitations may be indicated by curves departing from a straight line (see 11.2) or the isothermal aging test not closely agreeing with the results predicted by the calculated kinetic values. In particular, this method is not applicable to reactions that are partially inhibited. The technique may not work with reactions that include simultaneous or consecutive reaction steps. This method may not apply to materials that undergo phase transitions if the reaction rate is significant at the transition temperature.1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Information importante
Pour la consultation de ce document, l'installation du plug in FileOpen est nécessaire.
A la demande de l’éditeur, la consultation du document est disponible uniquement en version PDF avec une utilisation monoposte et l'impression n'est pas autorisée. Si vous n’êtes pas la personne destinée à utiliser ce document, ne pas le télécharger sur votre poste, sinon cette dernière ne pourra pas l’ouvrir.
En cas de problème, merci de cliquer ici pour contacter le support client
Si ce n'est pas déjà fait, téléchargez le plug-in ICI
Consultez ICI nos prérequis.
Informations générales

Collections

Normes américaines ASTM

Date de publication

novembre 2004

Référence

ASTM E698-04
Résumé
Standard Test Method for Arrhenius Kinetic Constants for Thermally Unstable Materials

1.1 This method covers the determination of the overall kinetic parameters for exothermic reactions.1.2 The kinetic parameters are obtained from differential scanning calorimetry (DSC) curves (see Section 3).1.3 This technique is applicable to reactions whose behavior can be described by the Arrhenius equation and the general rate law.1.4 Limitations-There are cases where this technique is not applicable. Limitations may be indicated by curves departing from a straight line (see 11.2) or the isothermal aging test not closely agreeing with the results predicted by the calculated kinetic values. In particular, this method is not applicable to reactions that are partially inhibited. The technique may not work with reactions that include simultaneous or consecutive reaction steps. This method may not apply to materials that undergo phase transitions if the reaction rate is significant at the transition temperature.1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Normes remplacées (1)
ASTM E698-01
avril 2001
Norme Annulée
Standard Test Method for Arrhenius Kinetic Constants for Thermally Unstable Materials

Norme remplacée par (1)
ASTM E698-05
mars 2005
Norme Annulée
Standard Test Method for Arrhenius Kinetic Constants for Thermally Unstable Materials

1.1 This method covers the determination of the overall kinetic parameters for exothermic reactions using the Flynn/Wall/Ozawa method and differential scanning calorimetry.1.2 This technique is applicable to reactions whose behavior can be described by the Arrhenius equation and the general rate law.1.3 LimitationsThere are cases where this technique is not applicable. Limitations may be indicated by curves departing from a straight line (see ) or the isothermal aging test not closely agreeing with the results predicted by the calculated kinetic values. In particular, this method is not applicable to reactions that are partially inhibited. The technique may not work with reactions that include simultaneous or consecutive reaction steps. This method may not apply to materials that undergo phase transitions if the reaction rate is significant at the transition temperature.1.4 SI units are the standard.This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement

Je découvre COBAZ