IEC 60076-7:2018
Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers
IEC 60076-7:2018 is applicable to mineral-oil-immersed transformers. It describes the effect of operation under various ambient temperatures and load conditions on transformer life. This document provides guidance for the specification and loading of power transformers from the point of view of operating temperatures and thermal ageing. It provides recommendations for loading above the nameplate rating and guidance for the planner to choose appropriate rated quantities and loading conditions for new installations. This edition includes the following significant technical changes with respect to the previous edition:a) title has been updated from "oil-immersed power transformers" to "mineral-oil-immersed transformers";b) insulation life is updated by considering latest research findings;c) temperature limits have been reviewed and maximum core temperature is recommended;d) number of fibre optic sensors is recommended for temperature rise test;e) Q, S and H factors are considered;f) thermal models are revised and rewritten in generally applicable mathematical form;g) geomagnetic induced currents are briefly discussed and corresponding temperature limits are suggested;h) extensive literature review has been performed and a number of references added to bibliography.
IEC 60076-7:2018 is applicable to mineral-oil-immersed transformers. It describes the effect of operation under various ambient temperatures and load conditions on transformer life. This document provides guidance for the specification and loading of power transformers from the point of view of operating temperatures and thermal ageing. It provides recommendations for loading above the nameplate rating and guidance for the planner to choose appropriate rated quantities and loading conditions for new installations. This edition includes the following significant technical changes with respect to the previous edition:
a) title has been updated from "oil-immersed power transformers" to "mineral-oil-immersed transformers";
b) insulation life is updated by considering latest research findings;
c) temperature limits have been reviewed and maximum core temperature is recommended;
d) number of fibre optic sensors is recommended for temperature rise test;
e) Q, S and H factors are considered;
f) thermal models are revised and rewritten in generally applicable mathematical form;
g) geomagnetic induced currents are briefly discussed and corresponding temperature limits are suggested;
h) extensive literature review has been performed and a number of references added to bibliography.
Est applicable aux transformateurs immergés dans l'huile et décrit l'effet du fonctionnement pour diverses températures ambiantes et conditions de charge durant la vie du transformateur.
Le service Exigences vous aide à repérer rapidement au sein du texte normatif :
- les clauses impératives à satisfaire,
- les clauses non indispensables mais utiles à connaitre, telles que les permissions et les recommandations.
L’identification de ces types de clauses repose sur le document « Directives ISO/IEC, Partie 2 - Principes et règles de structure et de rédaction des documents ISO » ainsi que sur une liste de formes verbales constamment enrichie.
Avec Exigences, accédez rapidement à l’essentiel du texte normatif !

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.
Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !
Demandez votre démo live gratuite, sans engagement
Je découvre COBAZ