IEC 61000-4-23:2016

IEC 61000-4-23:2016

octobre 2016
Norme internationale En vigueur

Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances

IEC 61000-4-23:2016(E) provides a protective devices test method for HEMP and other radiated disturbances. It is primarily intended for HEMP testing but can be applied to other externally generated radiated disturbances where appropriate. It provides a brief description of the most important concepts for testing of shielding elements. For each test, the following basic information is provided:- theoretical foundation of the test (the test concepts);- test set-up including outside-to-in and inside-to-out measurements;- required equipment;- test procedures;- data processing.This international standard does not provide information on requirements for specific levels for testing. Due to the available space, a transmitting antenna position outside the barrier has mainly been suggested. However, nowadays, many EMP protection facilities in practical use do not actually have enough space available outside the electromagnetic barrier due to physical constraints such as concrete walls or soil to allow the method described in IEC 61000-4-23:2000 (edition 1) to be applied correctly. From experience many facilities have available space for a 1 m separation or less only. Therefore, in many practical cases it is not possible to measure shielding effectiveness according to the test method of previous documents. The constructors for EMP protection facilities are also unwilling to build facilities with extra space for measurements with the transmitting antenna outside the barrier due to the great expense and inefficiency of the operational working area for new or existing buildings. This document provides additionally a method that allows the transmitting antenna to be placed inside the enclosure and the receiving antenna outside the barrier ('inside-to-out' method). Annex F includes test set-up and procedure examples. This second edition cancels and replaces the first edition published in 2000. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) updates to the shielding effectiveness (SE) test method in Clause 5;b) a new Annex F describing methods for testing 'inside-to-out' has been added.

Informations générales

Collections

Normes internationales IEC

Date de publication

octobre 2016

Nombre de pages

104 p.

Référence

IEC 61000-4-23:2016

Numéro de tirage

2
Résumé
Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances

IEC 61000-4-23:2016(E) provides a protective devices test method for HEMP and other radiated disturbances. It is primarily intended for HEMP testing but can be applied to other externally generated radiated disturbances where appropriate. It provides a brief description of the most important concepts for testing of shielding elements. For each test, the following basic information is provided:
- theoretical foundation of the test (the test concepts);
- test set-up including outside-to-in and inside-to-out measurements;
- required equipment;
- test procedures;
- data processing.
This international standard does not provide information on requirements for specific levels for testing. Due to the available space, a transmitting antenna position outside the barrier has mainly been suggested. However, nowadays, many EMP protection facilities in practical use do not actually have enough space available outside the electromagnetic barrier due to physical constraints such as concrete walls or soil to allow the method described in IEC 61000-4-23:2000 (edition 1) to be applied correctly. From experience many facilities have available space for a 1 m separation or less only. Therefore, in many practical cases it is not possible to measure shielding effectiveness according to the test method of previous documents. The constructors for EMP protection facilities are also unwilling to build facilities with extra space for measurements with the transmitting antenna outside the barrier due to the great expense and inefficiency of the operational working area for new or existing buildings. This document provides additionally a method that allows the transmitting antenna to be placed inside the enclosure and the receiving antenna outside the barrier ('inside-to-out' method). Annex F includes test set-up and procedure examples. This second edition cancels and replaces the first edition published in 2000. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) updates to the shielding effectiveness (SE) test method in Clause 5;
b) a new Annex F describing methods for testing 'inside-to-out' has been added.
Normes remplacées (1)
IEC 61000-4-23:2000
octobre 2000
Norme internationale Annulée
Compatibilité électromagnétique (CEM) - Partie 4-23: Techniques d'essai et de mesure - Méthodes d'essai pour les dispositifs de protection pour perturbations IEMN-HA et autres perturbations rayonnées

Etudie les principales raisons justifiant les essais pratiqués sur les dispositifs IEMN-HA et fournit une courte description des concepts les plus importants relatifs aux essais des éléments de blindage. Pour chaque essai, les informations de base suivantes sont fournies: - fondement théorique de l'essai (le concept d'essai); - montage d'essai; - matériel requis; - procédures d'essai; - traitement de données.

ZOOM SUR... le service Exigences
Pour respecter une norme, vous avez besoin de comprendre rapidement ses enjeux afin de déterminer son impact sur votre activité.

Le service Exigences vous aide à repérer rapidement au sein du texte normatif :
- les clauses impératives à satisfaire,
- les clauses non indispensables mais utiles à connaitre, telles que les permissions et les recommandations.

L’identification de ces types de clauses repose sur le document « Directives ISO/IEC, Partie 2 - Principes et règles de structure et de rédaction des documents ISO » ainsi que sur une liste de formes verbales constamment enrichie.

Avec Exigences, accédez rapidement à l’essentiel du texte normatif !

Avec Exigences, accédez rapidement à l'essentiel du texte normatif !
Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement

Je découvre COBAZ