IEC 62873-3-2:2020

IEC 62873-3-2:2020

novembre 2020
Norme internationale En vigueur

Residual current operated circuit-breakers for household and similar use - Part 3-2: Particular requirements for devices with flat quick-connect terminations

IEC 62873-3-2:2020 applies to devices equipped with flat quick-connect terminations consisting of a male tab with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer's instructions, for rated currents up to and including 16 A. This second edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- Modification of the scope to address other devices in addition to RCDs;- Modification of 8.1 so that IEC 62873-3-2 can be referred to by other product standards in addition to those for RCDs;- Modification of 9.1 so that IEC 62873-3-2 can be referred to by other product standards in addition to those for RCDs.

Informations générales

Collections

Normes internationales IEC

Date de publication

novembre 2020

Nombre de pages

13 p.

Référence

IEC 62873-3-2:2020

Numéro de tirage

2
Résumé
Residual current operated circuit-breakers for household and similar use - Part 3-2: Particular requirements for devices with flat quick-connect terminations

IEC 62873-3-2:2020 applies to devices equipped with flat quick-connect terminations consisting of a male tab with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer's instructions, for rated currents up to and including 16 A. This second edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Modification of the scope to address other devices in addition to RCDs;
- Modification of 8.1 so that IEC 62873-3-2 can be referred to by other product standards in addition to those for RCDs;
- Modification of 9.1 so that IEC 62873-3-2 can be referred to by other product standards in addition to those for RCDs.
Normes remplacées (1)
IEC 62873-3-2:2016
septembre 2016
Norme internationale Annulée
Residual current operated circuit-breakers for household and similar use - Part 3-2: Particular requirements for RCDs with flat quick-connect terminations

IEC 62873-3-2:2016(E) applies to RCDs equipped with flat quick-connect terminations consisting of a male tab (see 3.2) with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer's instructions, for rated currents up to and including 16 A.

ZOOM SUR... le service Exigences
Pour respecter une norme, vous avez besoin de comprendre rapidement ses enjeux afin de déterminer son impact sur votre activité.

Le service Exigences vous aide à repérer rapidement au sein du texte normatif :
- les clauses impératives à satisfaire,
- les clauses non indispensables mais utiles à connaitre, telles que les permissions et les recommandations.

L’identification de ces types de clauses repose sur le document « Directives ISO/IEC, Partie 2 - Principes et règles de structure et de rédaction des documents ISO » ainsi que sur une liste de formes verbales constamment enrichie.

Avec Exigences, accédez rapidement à l’essentiel du texte normatif !

Avec Exigences, accédez rapidement à l'essentiel du texte normatif !
Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement

Je découvre COBAZ