IEC TR 62453-515:2009
Field device tool (FDT) interface specification - Part 515: Communication implementation for common object model - IEC 61784 CPF 15
IEC/TR 62453-515:2009(E) provides information for integrating IEC 61784-2 CPF 15 (Modbus TCP®) and Modbus Serial Line®) protocol support into FDT systems based on COM implementation. This part is to be used in conjunction with IEC/TR 62453-41. It only specifies the mapping of Modbus parameters to FDT data types. For restrictions of protocol specific parameters concerning allowed values and concerning limitations of arrays used in the definition of FDT data types, refer to IEC 61158-5-15 and the MODBUS Application Protocol Specification.
IEC/TR 62453-515:2009(E) provides information for integrating IEC 61784-2 CPF 15 (Modbus TCP®) and Modbus Serial Line®) protocol support into FDT systems based on COM implementation. This part is to be used in conjunction with IEC/TR 62453-41. It only specifies the mapping of Modbus parameters to FDT data types. For restrictions of protocol specific parameters concerning allowed values and concerning limitations of arrays used in the definition of FDT data types, refer to IEC 61158-5-15 and the MODBUS Application Protocol Specification.
provides information for integrating the HART protocol into the FDT interface specification (IEC 62453-1). This PAS neither contains the FDT specification nor modifies it.
provides information for integrating the FOUNDATION FIELDBUS (FF) protocol into the FDT interface specification (IEC 62453-1). describes communication schemas, protocol-specific extensions and the means for block (e.g. transducer, resource or function blocks) representation.
provides information for integrating the PROFIBUS protocol into the FDT interface specification (IEC 62453-1). This PAS neither contains the FDT specification nor modifies it.
provides information for integrating the INTERBUS® protocol into the FDT interface specification (IEC 62453-1).
includes the engineering and commissioning of field devices. Functionality for documentation and audit trail support is also considered. Examples and use cases are mainly given for actors, sensors and remote I/Os. Of course, FDT is prepared to be used for devices like drives, analyzers, recorders, etc. as well. The FDT interfaces are designed in such a way as to support all significant fieldbus protocols. The main focus of this version of FDT does not lie on any specific fieldbus protocol. Due to the scalable structure of FDT it will be easy to add new schemas in order to extend the scope to new protocols.
IEC TR 62453-51-150:2017(E) which is a Technical Report, provides information for integrating IEC 61784-2 CPF 15 (Modbus TCP®) and Modbus Serial Line® protocol support into FDT systems based on COM implementation. This part is to be used in conjunction with IEC TR 62453-41. This part of IEC 62453 only specifies the mapping of Modbus parameters to FDT data types. For restrictions of protocol specific parameters concerning allowed values and concerning limitations of arrays used in the definition of FDT data types, refer to IEC 61158-5-15 and the MODBUS Application Protocol Specification. This part of IEC 62453 specifies the implementation of communication and other services based on IEC 62453?315. This document neither contains the FDT specification nor modifies it. .
COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.
Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !
Demandez votre démo live gratuite, sans engagement
Je découvre COBAZ