IEEE 117

IEEE 117

mai 2016
Norme En vigueur

IEEE Standard Test Procedure for Thermal Evaluation of Systems of Insulating Materials for Random-Wound AC Electric Machinery

The standard test procedure for the thermal evaluation and qualification of electrical insulation systems (EISs) for random-wound ac electric machinery, where thermal degradation is the dominating aging factor, is described. The relative thermal performance of a candidate EIS is compared to that of a reference EIS. Insulation systems for such machinery with input voltage of up to 600 V at 50/60 Hz are described in this standard. A statistical method for establishing a relative life-temperature relationship for an insulation system is also described. To have any significance, the reference insulation system must be supported with adequate field service data. Evaluation of insulation systems for use in air-cooled, random-wound ac electric machinery with “usual service conditions” is this procedure’s intent. This procedure, on its own, does not cover insulation systems such as exposure to conducting contaminates, radiation, inverter applications, or operation in oils, refrigerants, or other media that potentially degrades insulating materials.

Informations générales

Collections

Normes américaines IEEE

Date de publication

mai 2016

Nombre de pages

34 p.

Référence

IEEE 117
Résumé
IEEE Standard Test Procedure for Thermal Evaluation of Systems of Insulating Materials for Random-Wound AC Electric Machinery

The standard test procedure for the thermal evaluation and qualification of electrical insulation systems (EISs) for random-wound ac electric machinery, where thermal degradation is the dominating aging factor, is described. The relative thermal performance of a candidate EIS is compared to that of a reference EIS. Insulation systems for such machinery with input voltage of up to 600 V at 50/60 Hz are described in this standard. A statistical method for establishing a relative life-temperature relationship for an insulation system is also described. To have any significance, the reference insulation system must be supported with adequate field service data. Evaluation of insulation systems for use in air-cooled, random-wound ac electric machinery with “usual service conditions” is this procedure’s intent. This procedure, on its own, does not cover insulation systems such as exposure to conducting contaminates, radiation, inverter applications, or operation in oils, refrigerants, or other media that potentially degrades insulating materials.
Besoin d’identifier, de veiller et de décrypter les normes ?

COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.

Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !

Demandez votre démo live gratuite, sans engagement

Je découvre COBAZ