IEC 60970:2007

IEC 60970:2007

July 2007
International standard Current

Insulating liquids - Methods for counting and sizing particles

Describes the sampling procedures and methods for the determination of particle concentration and size distribution. Three methods are specified. One uses an automatic particle size analyser, working on the light interruption principle. The other two use an optical microscope, in either the transmitted light or incident light mode, to count particles collected on the surface of a membrane filter. The optical microscope methods are described in ISO 4407. All three methods are applicable to both used and unused insulating liquids. Annex A contains an alternative sampling procedure using a syringe and Annex B reports a reference for the calibration of automatic particle counters. The significant technical changes with respect to the previous edition are as follows: - new calibration procedures for automated laser particle; - three figures contamination code; - new procedure of sample pre-treatment when automated laser counter method are used.

Main informations

Collections

International IEC standards

Publication date

July 2007

Number of pages

37 p.

Reference

IEC 60970:2007
Sumary
Insulating liquids - Methods for counting and sizing particles

Describes the sampling procedures and methods for the determination of particle concentration and size distribution. Three methods are specified. One uses an automatic particle size analyser, working on the light interruption principle. The other two use an optical microscope, in either the transmitted light or incident light mode, to count particles collected on the surface of a membrane filter. The optical microscope methods are described in ISO 4407. All three methods are applicable to both used and unused insulating liquids. Annex A contains an alternative sampling procedure using a syringe and Annex B reports a reference for the calibration of automatic particle counters. The significant technical changes with respect to the previous edition are as follows: - new calibration procedures for automated laser particle; - three figures contamination code; - new procedure of sample pre-treatment when automated laser counter method are used.
Replaced standards (1)
IEC 60970:1989
June 1989
International standard Cancelled
Methods for counting and sizing particles in insulating liquids

Describes sampling procedures and methods for determining particle concentration and particle size distribution. Three methods are recommended, one using an automatic particle size analyzer and two based on the counting, with an optical microscope, of particles on the surface of a filtering membrane. All methods are applicable to both unused liquids and liquids in service.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ