ISO 14461-2:2005
Milk and milk products - Quality control in microbiological laboratories - Part 2 : determination of the reliability of colony counts of parallel plates and subsequent dilution steps
ISO 14461-2|IDF 169-2:2005 describes a routine procedure for the evaluation of results of the enumeration of microorganisms using colony-count methods with subsequent 10-fold dilution steps and one plate or two parallel plates within each dilution step. This routine procedure is applied regularly in each laboratory performing colony counts. It provides criteria for the acceptability of differences between the results from parallel plates and subsequent dilution steps, as follows.The results (colony counts) obtained from parallel plates are compared with tabulated limits for given colony counts. If these limits are exceeded, a technical problem when performing the parallel determinations may be indicated.The results (sums of colony counts) of two parallel plates of two subsequent 10-fold dilution steps are compared with tabulated limits for given sums of colony counts. If these limits are exceeded, a technical problem when performing the dilutions may be indicated.If the limits mentioned above are exceeded in more cases than expected, this indicates that the test procedure lacks reliability.
ISO 14461-2|IDF 169-2:2005 describes a routine procedure for the evaluation of results of the enumeration of microorganisms using colony-count methods with subsequent 10-fold dilution steps and one plate or two parallel plates within each dilution step.
This routine procedure is applied regularly in each laboratory performing colony counts. It provides criteria for the acceptability of differences between the results from parallel plates and subsequent dilution steps, as follows.
The results (colony counts) obtained from parallel plates are compared with tabulated limits for given colony counts. If these limits are exceeded, a technical problem when performing the parallel determinations may be indicated.
The results (sums of colony counts) of two parallel plates of two subsequent 10-fold dilution steps are compared with tabulated limits for given sums of colony counts. If these limits are exceeded, a technical problem when performing the dilutions may be indicated.
If the limits mentioned above are exceeded in more cases than expected, this indicates that the test procedure lacks reliability.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ