ISO 15724:2001

ISO 15724:2001

December 2001
International standard Current

Metallic and other inorganic coatings - Electrochemical measurement diffusible hydrogen in steels - Barnacle electrode method

This International Standard describes a method that uses an electronic hydrogen detection instrument for measuring relative, diffusible hydrogen concentrations in bare steels or in plated steels after the coating has been removed. It is assumed that the hydrogen is uniformly distributed throughout a part. The method does not measure actual hydrogen concentration. However, oxidation current densities measured against time provide a useful indication of relative hydrogen concentrations and, therefore, the measurements can be used for comparison purposes. The method may be used as a quality control procedure as it does provide a quick means of measuring the effectiveness of pre- and/or post-plating heat treatments or of monitoring hydrogen uptake during plating or due to corrosion. It is important to note that the absence of failure in a particular test does not provide confirmation of complete elimination of hydrogen embrittlement because no one test method can provide all the data necessary to evaluate the degree of hydrogen degradation. For unplated parts the method is non-destructive; however, for plated parts the coating has to be removed prior to measurement by a means proven not to damage the steel or to introduce hydrogen. This test method is limited to: — carbon and alloy steels, excluding austenitic stainless steels (see note 1); — flat specimens to which the cell can be attached (see note 2); — measurements at room temperature ( ). NOTE 1 If this method is used for austenitic stainless steels and other face centred cubic (FCC) alloys, measurement times and interpretation of results will have to be determined because of the different kinetics involved. NOTE 2 For slightly curved surfaces it is essential to define an area that is reproducible. The area calculation will be different from that described in this International Standard. NOTE 3 The method can be applied to small parts, however, this necessitates some modification of the technique, procedure and interpretation of results.

View the extract
Main informations

Collections

International ISO standards

Publication date

December 2001

Number of pages

10 p.

Reference

ISO 15724:2001

ICS Codes

25.220.40   Metallic coatings

Print number

1 - 11/01/2002
Sumary
Metallic and other inorganic coatings - Electrochemical measurement diffusible hydrogen in steels - Barnacle electrode method

This International Standard describes a method that uses an electronic hydrogen detection instrument for measuring

relative, diffusible hydrogen concentrations in bare steels or in plated steels after the coating has been removed. It is

assumed that the hydrogen is uniformly distributed throughout a part.

The method does not measure actual hydrogen concentration. However, oxidation current densities measured

against time provide a useful indication of relative hydrogen concentrations and, therefore, the measurements can be

used for comparison purposes. The method may be used as a quality control procedure as it does provide a quick

means of measuring the effectiveness of pre- and/or post-plating heat treatments or of monitoring hydrogen uptake

during plating or due to corrosion.

It is important to note that the absence of failure in a particular test does not provide confirmation of complete

elimination of hydrogen embrittlement because no one test method can provide all the data necessary to evaluate

the degree of hydrogen degradation.

For unplated parts the method is non-destructive; however, for plated parts the coating has to be removed prior to

measurement by a means proven not to damage the steel or to introduce hydrogen.

This test method is limited to:

— carbon and alloy steels, excluding austenitic stainless steels (see note 1);

— flat specimens to which the cell can be attached (see note 2);

— measurements at room temperature ( ).

NOTE 1 If this method is used for austenitic stainless steels and other face centred cubic (FCC) alloys, measurement times and

interpretation of results will have to be determined because of the different kinetics involved.

NOTE 2 For slightly curved surfaces it is essential to define an area that is reproducible. The area calculation will be different

from that described in this International Standard.

NOTE 3 The method can be applied to small parts, however, this necessitates some modification of the technique, procedure

and interpretation of results.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ