ISO 16283-1:2014
Acoustics - Field measurement of sound insulation in buildings and of building elements - Part 1 : airborne sound insulation
ISO 16283-1:2014 specifies procedures to determine the airborne sound insulation between two rooms in a building using sound pressure measurements. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the airborne sound insulation in unfurnished or furnished rooms where the sound field may or may not approximate to a diffuse field. The measured airborne sound insulation is frequency-dependent and can be converted into a single number quantity to characterize the acoustic performance using the rating procedures in ISO 717‑1.
ISO 16283-1:2014 specifies procedures to determine the airborne sound insulation between two rooms in a building using sound pressure measurements. These procedures are intended for room volumes in the range from 10 m3 to 250 m3 in the frequency range from 50 Hz to 5 000 Hz. The test results can be used to quantify, assess and compare the airborne sound insulation in unfurnished or furnished rooms where the sound field may or may not approximate to a diffuse field. The measured airborne sound insulation is frequency-dependent and can be converted into a single number quantity to characterize the acoustic performance using the rating procedures in ISO 717‑1.
ISO 140-14:2004 concerns field measurements of airborne sound insulation and impact sound insulation, and is to be used as a supplement to ISO 140-4 and ISO 140-7. It contains guidelines on sound insulation measurements in special situations in the field not directly covered by ISO 140-4 and ISO 140-7. The basic standards ISO 140-4 and ISO 140-7 specify the measurement procedure in detail under ideal conditions, but give only little information on how to establish a suitable measurement set-up in rooms differing from simple box-shaped rooms of normal living room size. When it comes to very large rooms, long and narrow rooms, staircases, coupled rooms, etc., no guidance is given in the basic standards, which is why the guidelines in ISO 140-14:2004 have been prepared. Use of the guidelines will contribute to improvement in the reproducibility of building acoustics field measurements and furthermore facilitate the performance of measurements by avoiding time-consuming considerations in actual measurement situations. ISO 140-14:2004 is primarily applicable to measurements in rooms in dwellings, schools, hotels, etc., with volumes less than 250 m3.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ