Ergonomics - Accessible design - Sound pressure levels of auditory signals for consumer products

ISO 24501:2010 specifies methods for determining the sound pressure level range of auditory signals so that the users of consumer products, including people with age-related hearing loss, can hear the signal properly in the presence of interfering sounds.Auditory signals, in ISO 24501:2010, refer to sounds with a fixed frequency (also called beep sounds) and do not include variable frequency sounds, melodic sounds, or voice guides.ISO 24501:2010 is applicable to auditory signals which are heard at an approximate maximum distance of 4 m from the product, as long as no physical barrier exists between the product and the user. It is not applicable to auditory signals heard through a head receiver or earphones, or to those heard with the ear located very near to the sound source because of the interference of the head with sound propagation.ISO 24501:2010 does not specify the sound pressure level of auditory signals regulated by other statutes, such as those for fire alarms, gas leakages and crime prevention, nor does it specify auditory signals particular to a communication tool such as telephones.ISO 24501:2010 does not specify auditory danger signals for public or work areas which are covered in ISO 7731, ISO 8201, and ISO 11429.

View the extract
Main informations

Collections

National standards and national normative documents

Thematics

Sécurité, Silver économie, Gestion des risques et SST, Accessibilité, QSE

Publication date

February 2011

Number of pages

30 p.

Reference

NF EN ISO 24501

ICS Codes

11.180.15   Aids for deaf and hearing impaired people
13.180   Ergonomics

Classification index

X35-402

Print number

1 - 31/01/2011

International kinship

European kinship

EN ISO 24501:2010
Sumary
Ergonomics - Accessible design - Sound pressure levels of auditory signals for consumer products

ISO 24501:2010 specifies methods for determining the sound pressure level range of auditory signals so that the users of consumer products, including people with age-related hearing loss, can hear the signal properly in the presence of interfering sounds.

Auditory signals, in ISO 24501:2010, refer to sounds with a fixed frequency (also called beep sounds) and do not include variable frequency sounds, melodic sounds, or voice guides.

ISO 24501:2010 is applicable to auditory signals which are heard at an approximate maximum distance of 4 m from the product, as long as no physical barrier exists between the product and the user. It is not applicable to auditory signals heard through a head receiver or earphones, or to those heard with the ear located very near to the sound source because of the interference of the head with sound propagation.

ISO 24501:2010 does not specify the sound pressure level of auditory signals regulated by other statutes, such as those for fire alarms, gas leakages and crime prevention, nor does it specify auditory signals particular to a communication tool such as telephones.

ISO 24501:2010 does not specify auditory danger signals for public or work areas which are covered in ISO 7731, ISO 8201, and ISO 11429.

Table of contents
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Termes et définitions
    2
  • 4 Symboles
    2
  • 5 Plage des niveaux de pression acoustique du signal auditif
    3
  • 5.1 Généralités
    3
  • 5.2 Lorsque l'effet masquant d'un son parasite n'est pas pris en compte
    3
  • 5.3 Lorsque l'effet masquant d'un son parasite est pris en compte
    4
  • Annexe A (normative) Méthode de mesurage du niveau de pression acoustique d'un signal auditif
    8
  • Annexe B (normative) Méthode de mesure du niveau de pression acoustique du son parasite
    12
  • Annexe C (informative) Exemple de l'enregistrement des conditions et des résultats du mesurage
    15
  • Annexe D (informative) Exemples de mesurage et de détermination de plage du niveau de pression acoustique d'un signal auditif
    17
  • Bibliographie
    22
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ