NF EN ISO 8537

NF EN ISO 8537

October 2008
Standard Cancelled

Sterile single-use syringes, with or without needle, for insulin

ISO 8537:2007 specifies requirements and test methods for sterile syringes, with or without needles, solely for the injection of insulin. The syringes are single-use only, primarily for use in humans. It covers syringes for use with 40 units of insulin/ml (U-40) and 100 units of insulin/ml (U-100).Sterile syringes specified in ISO 8537:2007 are intended for use soon after filling as they are not suitable for containing insulin over extended periods of time.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

October 2008

Number of pages

31 p.

Reference

NF EN ISO 8537

ICS Codes

11.040.25   Syringes, needles and catheters

Classification index

S93-005

Print number

1 - 08/09/2008

International kinship

European kinship

EN ISO 8537:2008
Sumary
Sterile single-use syringes, with or without needle, for insulin

ISO 8537:2007 specifies requirements and test methods for sterile syringes, with or without needles, solely for the injection of insulin. The syringes are single-use only, primarily for use in humans. It covers syringes for use with 40 units of insulin/ml (U-40) and 100 units of insulin/ml (U-100).

Sterile syringes specified in ISO 8537:2007 are intended for use soon after filling as they are not suitable for containing insulin over extended periods of time.

Replaced standards (2)
NF EN ISO 8537
October 1994
Standard Cancelled
Sterile single-use syringes, with or without needle, for insulin

NF EN ISO 8537/A1
February 2001
Standard Cancelled
Sterile single-use syringes, with or without needle, for insulin

Le présent document complète la norme de base NF EN ISO 8537 de 1994 (indice de classement : S 93-005). L'Amendement 1 à l'ISO 8537:1991 avait été soumis à une enquête parallèle ISO/CEN en 1998 ; cet Amendement avait pour objet la prise en compte des aiguilles plus courtes et plus fines qui sont largement utilisées dans le monde, en apportant des modifications sur certains articles de l'ISO 8537, et était lié à l'ISO 9626:1991, Tubes d'aiguilles en acier inoxydable pour la fabrication de matériel médical, qui est en cours d'amendement pour inclure les nouvelles dimensions des tubes d'aiguilles. Étant donné que l'amendement de l'ISO 9626:1991 a été retardé, le présent Amendement à l'ISO 8537 est indépendant du texte de l'ISO 9626. Il n'est pas applicable aux tubes d'aiguilles de diamètre extérieur de 0,38 mm, car cette dimension n'est pas incluse dans l'ISO 9626.

Standard replaced by (1)
NF EN ISO 8537
June 2016
Standard Current
Sterile single-use syringes, with or without needle, for insulin

ISO 8537:2016 specifies requirements and test methods for empty, sterile, single-use syringes, with or without needles, made of plastic materials and intended solely for the injection of insulin, with which the syringes are filled by the end user. This International Standard covers syringes intended for single-use only in humans and with insulins of various concentrations. The insulin syringes specified in this International Standard are intended for use (i.e. insulin injection) immediately after filling and are not intended to contain insulin for extended periods of time. ISO 8537:2016 excludes single-use syringes made of glass, syringes for use with power-driven syringe pumps, syringes that are pre-filled by the manufacturer, and syringes intended to be stored after filling (e.g. in a kit intended for filling by a pharmacist).

Table of contents
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Termes et définitions
    1
  • 4 Types de seringues
    3
  • 5 Absence de matière étrangère
    3
  • 6 Teneurs limites de matières étrangères
    3
  • 7 Lubrification des seringues et des aiguilles
    4
  • 8 Gamme de dimensions
    4
  • 9 Échelle graduée
    4
  • 10 Corps
    5
  • 11 Ensemble tête du piston/piston
    5
  • 12 Embout
    6
  • 13 Tubes d'aiguilles et aiguilles
    6
  • 14 Performances de la seringue montée
    6
  • 15 Emballage
    7
  • 16 Marquage
    8
  • Annexe A (normative) Liquide pour la détermination de l'acidité ou de l'alcalinité et des métaux extractibles
    11
  • Annexe B (normative) Méthode d'essai de détection, à l'aspiration, de fuites d'air au niveau de la tête du piston de la seringue
    12
  • Annexe C (normative) Méthode d'essai pour la détermination de la force requise pour actionner le piston
    14
  • Annexe D (normative) Propriétés des aiguilles et des tubes d'aiguille
    15
  • Annexe E (normative) Méthode d'essai pour la détermination de l'espace mort
    17
  • Annexe F (normative) Vérification de l'absence de fuite de liquide lors de la compression au niveau du piston, des jonctions entre l'embout de la seringue et l'embase ou entre l'aiguille et le corps
    18
  • Annexe G (normative) Méthode d'essai de détection, à l'aspiration, de fuites d'air au niveau des jonctions embout/embase ou aiguille/corps
    20
  • Annexe H (informative) Préparation de la solution d'essai pour la vérification de l'absence de substances pyrogènes et de toxicité
    21
  • Annexe I (informative) Symbole graphique nonréutilisable"22
  • Bibliographie23
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ