NF EN ISO 9612

NF EN ISO 9612

May 2009
Standard Current mandatory application standard

Acoustics - Determination of occupational noise exposure - Engineering method

ISO 9612:2009 specifies an engineering method for measuring workers' exposure to noise in a working environment and calculating the noise exposure level. ISO 9612:2009 deals with A-weighted levels but is applicable also to C-weighted levels. Three different strategies for measurement are specified. The method is useful where a determination of noise exposure to engineering grade is required, e.g. for detailed noise exposure studies or epidemiological studies of hearing damage or other adverse effects.The measuring process requires observation and analysis of the noise exposure conditions so that the quality of the measurements can be controlled. ISO 9612:2009 provides methods for estimating the uncertainty of the results.ISO 9612:2009 is not intended for assessment of masking of oral communication or assessment of infrasound, ultrasound and non-auditory effects of noise. It does not apply to the measurement of the noise exposure of the ear when hearing protectors are worn.Results of the measurements performed in accordance with ISO 9612:2009 can provide useful information when defining priorities for noise control measures.

View the extract
Main informations

Collections

National standards and national normative documents

Thematics

Gestion des risques et SST, QSE, Sécurité

Publication date

May 2009

Number of pages

58 p.

Reference

NF EN ISO 9612

ICS Codes

13.140   Noise with respect to human beings
17.140.20   Noise emitted by machines and equipment

Classification index

S31-084

Print number

1 - 27/05/2009

International kinship

European kinship

EN ISO 9612:2009
Sumary
Acoustics - Determination of occupational noise exposure - Engineering method

ISO 9612:2009 specifies an engineering method for measuring workers' exposure to noise in a working environment and calculating the noise exposure level. ISO 9612:2009 deals with A-weighted levels but is applicable also to C-weighted levels. Three different strategies for measurement are specified. The method is useful where a determination of noise exposure to engineering grade is required, e.g. for detailed noise exposure studies or epidemiological studies of hearing damage or other adverse effects.

The measuring process requires observation and analysis of the noise exposure conditions so that the quality of the measurements can be controlled. ISO 9612:2009 provides methods for estimating the uncertainty of the results.

ISO 9612:2009 is not intended for assessment of masking of oral communication or assessment of infrasound, ultrasound and non-auditory effects of noise. It does not apply to the measurement of the noise exposure of the ear when hearing protectors are worn.

Results of the measurements performed in accordance with ISO 9612:2009 can provide useful information when defining priorities for noise control measures.

Replaced standards (1)
NF S31-084
October 2002
Standard Cancelled
Acoustics - Method for measuring noise exposure levels in work environments

Le présent document définit une méthode de mesurage de l'exposition au bruit en milieu de travail en vue d'évaluer les niveaux d'exposition quotidienne au bruit et d'identifier les dépassements éventuels des seuils de niveaux de pression acoustique de crète.

Table of contents
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Symboles
  • 5 Instruments
  • 6 Méthodologie - Étapes chronologiques
  • 7 Analyse du travail
  • 8 Sélection des stratégies de mesurage
  • 9 Stratégie 1 - Mesurage basé sur la tâche
  • 10 Stratégie 2 - Mesurage basé sur la fonction
  • 11 Stratégie 3 - Mesurage sur une journée entière
  • 12 Mesurages
  • 13 Sources d'incertitude
  • 14 Calcul des incertitudes de mesure et présentation des résultats finaux
  • 15 Informations devant figurer dans le rapport
  • A Exemple de liste de contrôle permettant de s'assurer que les événements bruyants importants sont détectés au cours de l'analyse du travail
  • B Guide de sélection d'une stratégie de mesurage
  • C Évaluation des incertitudes de mesure
  • D Exemple de calcul du niveau d'exposition quotidienne au bruit en utilisant des mesurages basés sur la tâche
  • E Exemple de calcul du niveau d'exposition quotidienne au bruit en utilisant des mesurages basés sur la fonction
  • F Échantillon de calcul du niveau d'exposition quotidienne au bruit en utilisant des mesurages sur une journée entière
  • Bibliographie
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ