IEC 60092-350:2008
Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
This part of IEC 60092 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units. This third edition cancels and replaces the second edition published in 2001 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) the new insulating compounds contained in IEC 60092-351;b) the new sheathing compounds contained in IEC 60092-359;c) the publication of IEC 60092-376;d) the inclusion of cables up to 30 kV in the revision of IEC 60092-354;e) for use in a limited number of closely defined applications, the provision to allow the design of a single core cable with a single extrusion covering, having a thickness equal to that of both an insulation and sheath;f) new tests for the determination of enhanced cold properties, oil resistance, and resistance to drilling fluids.
This part of IEC 60092 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units. This third edition cancels and replaces the second edition published in 2001 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the new insulating compounds contained in IEC 60092-351;
b) the new sheathing compounds contained in IEC 60092-359;
c) the publication of IEC 60092-376;
d) the inclusion of cables up to 30 kV in the revision of IEC 60092-354;
e) for use in a limited number of closely defined applications, the provision to allow the design of a single core cable with a single extrusion covering, having a thickness equal to that of both an insulation and sheath;
f) new tests for the determination of enhanced cold properties, oil resistance, and resistance to drilling fluids.
L'IEC 60092-350:2014 fournit les exigences de construction générale et les méthodes d'essai à utiliser lors de la fabrication de câbles d'énergie, de commande et d'instrumentation à conducteurs en cuivre destinés à la connexion de systèmes électriques fixes à une tension au plus égale à 18/30(36) kV à bord des navires et des unités en mer (mobiles et fixes). Les types de câbles suivants ne sont pas inclus: - câbles à fibres optiques; - câbles sous-marins et ombilicaux; - câbles de données et câbles de communication; - câbles coaxiaux. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: a) il est fait référence à l'IEC 60092-360 pour les mélanges d'isolation et de gainage; b) les essais de décharges partielles ont été transférés à partir de l'IEC 60092-354 pour l'aligner avec l'IEC 60092-353; c) les exigences relatives à la résistance des huiles et des boues de forage (anciennes Annexes F et G) ont été transférées vers l'IEC 60092-360; d) les exigences relatives au cintrage à froid et aux chocs thermiques froids ont été améliorées; e) le document reflète les modifications des types de matériaux qui ont été introduites lors de l'élaboration de l'IEC 60092-353 et de l'IEC 60092-360. Le contenu du corrigendum de novembre 2018 a été pris en considération dans cet exemplaire.
COBAZ est la solution simple et efficace pour répondre aux besoins normatifs liés à votre activité, en France comme à l’étranger.
Disponible sur abonnement, CObaz est LA solution modulaire à composer selon vos besoins d’aujourd’hui et de demain. Découvrez vite CObaz !
Demandez votre démo live gratuite, sans engagement
Je découvre COBAZ