AFNOR C17-205

AFNOR C17-205

August 2014
Reference document Cancelled

Outdoor lighting installation - Determination of cross sectional Area of conductors and selection of protective devices

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

August 2014

Number of pages

38 p.

Reference

AFNOR C17-205

ICS Codes

29.260.10   Electrical installations for outdoor use
93.080.40   Street lighting and related equipment

Classification index

C17-205

Print number

1
Replaced standards (2)
UTE C17-205
July 2008
Reference document Cancelled
Outdoor lighting installation - Determination of cross-sectional Area of conductors and selection of protective devices

UTE C17-205 F1
June 2011
Interpretation sheet Cancelled
Fiche d'interprétation F1 du guide UTE C17-205 de juillet 2008

Standard replaced by (1)
FD C17-205
September 2017
Published document Current
Outdoor electrical installation - Determination of the cross-sectional area of conductors and selection of protective devices

Le présent document définit les principes relatifs à la détermination des sections des conducteurs et des choix des dispositifs de protection contre les surintensités des installations électriques extérieures relevant de la norme NF C 17-200. Le présent document ne s'applique pas aux installations réalisées en schéma IT qui doivent respecter les règles de la norme NF C 15-100.

Table of contents
View the extract
  • 1 Domaine d'application
    6
  • 2 Références normatives
    6
  • 3 Installation à basse tension
    6
  • 3.1 Généralités
    6
  • 3.2 Détermination du courant d'emploi IB
    7
  • 3.3 Détermination du courant d'allumage IA
    8
  • 3.4 Choix du dispositif de protection contre les surcharges
    10
  • 3.5 Détermination des sections de conducteurs (Sb) d'après les chutes de tension
    11
  • 3.6 Protection contre les courts-circuits (vérification de la section Sc)
    15
  • 3.7 Protection contre les contacts indirects en schéma TN (vérification de la section Sd)
    23
  • 4 Installation à haute tension
    26
  • 4.1 Généralités
    26
  • 4.2 Détermination du courant d'emploi
    26
  • 4.3 Détermination de la section des conducteurs Sh
    26
  • 4.4 Vérification des conditions de protection contre les courts-circuits et des contraintes thermiques des conducteurs
    28
  • 4.5 Vérification des conditions de protection contre les contacts indirects en schéma TNR (les masses du poste, la prise de terre du neutre et les masses de I'installation BT sont interconnectées)
    30
  • Annexe A Jeu d'essais
    31
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ