ASTM D6757-07(2013)

ASTM D6757-07(2013)

June 2013
Standard Cancelled

Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing

This specification covers inorganic fiber-reinforced organic felt, and inorganic fiber-based asphaltic and nonasphaltic felt underlayments for use as underlayment with steep-slope roofing products. The intent of this specification is to provide criteria for producing and evaluating underlayments with a significantly reduced tendency to wrinkle before or after the installation of steep roofing products. Materials shall be sampled and tested suitably to examine their conformance with performance requirements such as tear strength, pliability, behavior on heating, liquid water transmission, dimensional stability at low to high humidity conditions, and elongation.

Additional informations

1.1 This specification covers (1) inorganic fiber-reinforced organic felt underlayment and (2) inorganic fiber-based felt for use as underlayment with steep-slope roofing products. The intent of this specification is to provide criteria for producing and evaluating underlayments with a significantly reduced tendency to wrinkle before or after the installation of steep roofing products.

1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.

1.3 The following safety hazards caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.


Main informations

Collections

ASTM american standards

Publication date

June 2013

Number of pages

0 p.

Reference

ASTM D6757-07(2013)

Classification index

D6757-07R13
Sumary
Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing

This specification covers inorganic fiber-reinforced organic felt, and inorganic fiber-based asphaltic and nonasphaltic felt underlayments for use as underlayment with steep-slope roofing products. The intent of this specification is to provide criteria for producing and evaluating underlayments with a significantly reduced tendency to wrinkle before or after the installation of steep roofing products. Materials shall be sampled and tested suitably to examine their conformance with performance requirements such as tear strength, pliability, behavior on heating, liquid water transmission, dimensional stability at low to high humidity conditions, and elongation.

Standard replaced by (1)
ASTM D6757/D6757M-16
January 2016
Standard Cancelled
Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing

This specification covers inorganic fiber-reinforced organic felt, and inorganic fiber-based asphaltic and nonasphaltic felt underlayments for use as underlayment with steep-slope roofing products. The intent of this specification is to provide criteria for producing and evaluating underlayments with a significantly reduced tendency to wrinkle before or after the installation of steep roofing products. Materials shall be sampled and tested suitably to examine their conformance with performance requirements such as tear strength, pliability, behavior on heating, liquid water transmission, dimensional stability at low to high humidity conditions, and elongation.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ