1.1 These test methods cover the chemical analysis of stainless, heat-resisting, maraging, and other similar chromium-nickel-iron alloys having chemical compositions within the following limits:
|
| Element | Composition Range, % | ||
|
| Aluminum |
| 0.002 | to 5.50 |
|
| Boron |
| 0.001 | to 0.20 |
|
| Carbon |
| 0.01 | to 1.50 |
|
| Chromium |
| 0.01 | to 35.00 |
|
| Cobalt |
| 0.01 | to 15.00 |
|
| Niobium |
| 0.01 | to 4.00 |
|
| Copper |
| 0.01 | to 5.00 |
|
| Lead |
| 0.001 | to 0.50 |
|
| Manganese |
| 0.01 | to 20.00 |
|
| Molybdenum |
| 0.01 | to 7.00 |
|
| Nickel |
| 0.01 | to 48.00 |
|
| Nitrogen |
| 0.001 | to 0.50 |
|
| Phosphorus |
| 0.002 | to 0.35 |
|
| Selenium |
| 0.01 | to 0.50 |
|
| Silicon |
| 0.01 | to 4.00 |
|
| Sulfur |
| 0.002 | to 0.50 |
|
| Tantalum |
| 0.01 | to 0.80 |
|
| Tin |
| 0.001 | to 0.05 |
|
| Titanium |
| 0.01 | to 4.50 |
|
| Tungsten |
| 0.01 | to 4.50 |
|
| Vanadium |
| 0.005 | to 1.00 |
|
| Zirconium |
| 0.001 | to 0.20 |
1.2 The test methods in this standard are contained in the sections indicated below:
|
| Sections |
| Aluminum, Total, by the 8-Quinolinol Gravimetric Method (0.20 % to 7.00 %) | 119–126 |
| Aluminum, Total, by the 8-Quinolinol Spectrophotometric Method (0.003 % to 0.20 %) | 71–81 |
| Carbon, Total, by the Combustion–Thermal Conductivity Method–Discontinued 1986 | 153–163 |
| Carbon, Total, by the Combustion Gravimetric Method (0.05 % to 1.50 %)–Discontinued 2013 | 98–108 |
| Chromium by the Atomic Absorption Spectrometry Method (0.006 % to 1.00 %) | 202–211 |
| Chromium by the Peroxydisulfate Oxidation–Titration Method (0.10 % to 35.00 %) | 212–220 |
| Chromium by the Peroxydisulfate-Oxidation Titrimetric Method-Discontinued 1980 | 145–152 |
| Cobalt by the Ion-Exchange–Potentiometric Titration Method (2 % to 15 %) | 53–60 |
| Cobalt by the Nitroso-R-Salt Spectrophotometric Method (0.01 % to 5.0 %) | 61–70 |
| Copper by the Neocuproine Spectrophotometric Method (0.01 % to 5.00) %) | 109–118 |
| Copper by the Sulfide Precipitation-Electrodeposition Gravimetric Method (0.01 % to 5.00 %) | 82–89 |
| Lead by the Ion-Exchange-Atomic Absorption Spectrometry Method (0.001 % to 0.50 %) | 127–136 |
| Manganese by the Periodate Spectrophotometric Method (0.01 % to 5.00 %) | 9–18 |
| Molybdenum by the Ion Exchange–8-Hydroxyquinoline Gravimetric Method | 242–249 |
| Molybdenum by the Thiocyanate Spectrophotometric Method (0.01 % to 1.50 %) | 190–201 |
| Nickel by the Dimethylglyoxime Gravimetric Method (0.1 % to 48.0 %) | 172–179 |
| Phosphorus by the Alkalimetric Method (0.02 % to 0.35 %) | 164–171 |
| Phosphorus by the Molybdenum Blue Spectrophotometric Method (0.002 % to 0.35 %) | 19–30 |
| Silicon by the Gravimetric Method (0.05 % to 4.00 %) | 46–52 |
| Sulfur by the Gravimetric Method-Discontinued 1988 | 30–36 |
| Sulfur by the Combustion-Iodate Titration Method (0.005 % to 0.5 %)-Discontinued 2014 | 37–45 |
| Sulfur by the Chromatographic Gravimetric Method-Discontinued 1980 | 137–144 |
| Tin by the Solvent Extraction–Atomic Absorption Spectrometry Method (0.002 % to 0.10 %) | 180–189 |
| Tin by the Sulfide Precipitation-Iodometric Titration Method (0.01 % to 0.05 %) | 90–97 |
| Titanium by the Diantipyrylmethane Spectrophotometric Method (0.01 % to 0.35 %) | 231–241 |
| Vanadium by the Atomic Absorption Spectrometry Method (0.006 % to 0.15 %) | 221–230 |
1.3 Test methods for the determination of carbon and sulfur not included in this standard can be found in Test Methods E1019.
1.4 Some of the composition ranges given in 1.1 are too broad to be covered by a single test method and therefore this standard contains multiple test methods for some elements. The user must select the proper test method by matching the information given in the Scope and Interference sections of each method with the composition of the alloy to be analyzed.
1.5 The values stated in SI units are to be regarded as standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 6 and in special “Warning” paragraphs throughout these test methods.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Collections
Publication date
Number of pages
Reference
Classification index
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ