ASTM F1134-15(2025)

ASTM F1134-15(2025)

June 2025
Standard Current

Standard Specification for Insulation Resistance Monitor for Shipboard Electrical Motors and Generators

This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both. Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application. These insulation resistance monitors shall be classified in four types: Type I are alternating current generator monitors, Type II are alternating current generator monitors, Type III are direct current motor monitors, and Type IV are direct current generator monitors. The enclosure materials used in the construction of the monitors are to be flame-retardant and the current carrying terminals shall be made of corrosion resistant material. The monitors shall isolate their measuring circuit from the line voltage, while the motor is operating, by the use of an integral isolating relay. In the design of these monitors, environmental factors shall be considered: operating temperature range, sealing, inclination, humidity, and vibration. Also, the monitor relays, voltage characteristics and operating accuracy shall be considered in the design of these monitors. Each monitor shall be subjected to the following: visual and mechanical examination and operational test.

Important information
To view this document, the FileOpen plug-in must be installed.
The document is only available in PDF format for single-user use, and printing is not permitted.
If you haven't already done so, download the plug-inHERE
See HERE for our requirements.
Additional informations

1.1 This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both.

1.2 Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.4 The following safety hazards caveat pertains only to the test method described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Main informations

Collections

ASTM american standards

Publication date

June 2025

Number of pages

3 p.

Reference

ASTM F1134-15(2025)

Classification index

F1134-15R25
Sumary
Standard Specification for Insulation Resistance Monitor for Shipboard Electrical Motors and Generators

This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both. Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application. These insulation resistance monitors shall be classified in four types: Type I are alternating current generator monitors, Type II are alternating current generator monitors, Type III are direct current motor monitors, and Type IV are direct current generator monitors. The enclosure materials used in the construction of the monitors are to be flame-retardant and the current carrying terminals shall be made of corrosion resistant material. The monitors shall isolate their measuring circuit from the line voltage, while the motor is operating, by the use of an integral isolating relay. In the design of these monitors, environmental factors shall be considered: operating temperature range, sealing, inclination, humidity, and vibration. Also, the monitor relays, voltage characteristics and operating accuracy shall be considered in the design of these monitors. Each monitor shall be subjected to the following: visual and mechanical examination and operational test.