CISPR 14-2:2015
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 14-2:2015 deals with the electromagnetic immunity of appliances and similar apparatus for household and similar purposes that use electricity, as well as electric toys and electric tools, the rated voltage of the apparatus being not more than 250 V for single-phase apparatus to be connected to phase and neutral, and 480 V for other apparatus. Apparatus may incorporate motors, heating elements or their combination, may contain electric or electronic circuitry, and may be powered by the mains, by transformer, by batteries, or by any other electrical power source. Apparatus not intended for household use, but which nevertheless may require the immunity level, such as apparatus intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard, as far as they are included in CISPR 14-1. In addition, the following are also included in the scope of this standard:- microwave ovens for domestic use and catering;- cooking hobs and cooking ovens, heated by means of r.f. energy;- (single- and multiple-zone) induction cooking appliances;- appliances for personal care equipped with radiators in the range from UV to IR, inclusive (this includes visible light);- power supplies and battery chargers provided with or intended for apparatus within the scope of this standard.This second edition cancels and replaces the first edition published in 1997, Amendment 1:2001 and Amendment 2:2008. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- 5.1: For ESD tests on contacts of plugs and sockets the note ("The 4 kV contact discharge shall be applied to conductive accessible parts. Metallic contacts, such as in battery compartments or in socket outlets, are excluded from this requirement.") saying that no test on contacts is necessary has been removed. The IEC 61000-4-2 includes a detailed description how to deal with ESD on contacts and other surfaces. Also discharge on HCP and VCP is required by the basic standard IEC 61000-4-2.- 5.3 and 5.4: The tables for tests at D.C. power ports according IEC 61000-4-6 are aligned with the generic standards and are the same for 5.3 and 5.4.- 5.3 and 5.4: For EUT with single mains cable and not other cable, the test set-up as shown in Figure 2 shall be used. The set-up as described in Annex F of IEC 61000-4-6:2013 shall not be used.- 5.5: The IEC 61000-4-22 has been introduced as alternative method for testing radiated immunity.- 5.6: No line-to-earth surges are applied to products which do not have provision for connection to earth.
CISPR 14-2:2015 deals with the electromagnetic immunity of appliances and similar apparatus for household and similar purposes that use electricity, as well as electric toys and electric tools, the rated voltage of the apparatus being not more than 250 V for single-phase apparatus to be connected to phase and neutral, and 480 V for other apparatus. Apparatus may incorporate motors, heating elements or their combination, may contain electric or electronic circuitry, and may be powered by the mains, by transformer, by batteries, or by any other electrical power source. Apparatus not intended for household use, but which nevertheless may require the immunity level, such as apparatus intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard, as far as they are included in CISPR 14-1. In addition, the following are also included in the scope of this standard:
- microwave ovens for domestic use and catering;
- cooking hobs and cooking ovens, heated by means of r.f. energy;
- (single- and multiple-zone) induction cooking appliances;
- appliances for personal care equipped with radiators in the range from UV to IR, inclusive (this includes visible light);
- power supplies and battery chargers provided with or intended for apparatus within the scope of this standard.
This second edition cancels and replaces the first edition published in 1997, Amendment 1:2001 and Amendment 2:2008. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- 5.1: For ESD tests on contacts of plugs and sockets the note ("The 4 kV contact discharge shall be applied to conductive accessible parts. Metallic contacts, such as in battery compartments or in socket outlets, are excluded from this requirement.") saying that no test on contacts is necessary has been removed. The IEC 61000-4-2 includes a detailed description how to deal with ESD on contacts and other surfaces. Also discharge on HCP and VCP is required by the basic standard IEC 61000-4-2.
- 5.3 and 5.4: The tables for tests at D.C. power ports according IEC 61000-4-6 are aligned with the generic standards and are the same for 5.3 and 5.4.
- 5.3 and 5.4: For EUT with single mains cable and not other cable, the test set-up as shown in Figure 2 shall be used. The set-up as described in Annex F of IEC 61000-4-6:2013 shall not be used.
- 5.5: The IEC 61000-4-22 has been introduced as alternative method for testing radiated immunity.
- 5.6: No line-to-earth surges are applied to products which do not have provision for connection to earth.
Defines requirements for the electromagnetic immunity of electric and electronic toys.
Deals with the electromagnetic immunity of appliances and similar apparatus for household and similar purposes that use electricity, as well as electric toys and electric tools, the rated voltage of the apparatus being not more than 250 V for single-phase apparatus to be connected to phase and neutral, and 480 V for other apparatus. It specifies the immunity requirements in relation to continuous and transient, conducted and radiated electromagnetic disturbances, including electrostatic discharges, for the above-mentioned apparatus. Apparatus may incorporate motors, heating elements or their combination, may contain electric or electronic circuitry, and may be powered by the mains, by batteries, or by any other electrical power source. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered.
CISPR 14-2:2020 specifies the electromagnetic immunity requirements in the frequency range 0 Hz to 400 GHz that apply to appliances, electric tools and similar equipment as specified below, whether powered by AC or DC (including a battery). This document specifies immunity requirements for continuous and transient electromagnetic disturbances, both conducted and radiated. Unless otherwise specified, this document is applicable to all equipment in the scope of CISPR 14-1, namely: - household appliances or similar equipment; - electric tools; - similar equipment; - Refer to the Scope of the document for examples of equipment. Included in the scope of this document are also microwave ovens for domestic use or catering. Equipment which incorporate radio transmit/receive functions are included in the scope of this document. NOTE: For handling cases where equipment under the scope of this document is combined with transmit and/or receive radio functions, see Clause 8. Excluded from the scope of this document are: - equipment for which all electromagnetic immunity requirements are explicitly formulated in other CISPR or IEC standards; - equipment intended to be part of the fixed electrical installation of buildings (e.g. fuses, circuit breakers, cables and switches); - medical electrical equipment, including those in the scope of CISPR 14-1; - equipment used only in industrial environment; - equipment intended to be used exclusively in locations where special electromagnetic conditions exist (e.g. high electromagnetic fields nearby broadcast transmitting stations or high energy pulses nearby power generation stations); - equipment intended to be used exclusively on a vehicle, ship, boat or aircraft; - the effects of electromagnetic phenomena relating to the safety of apparatus (see IEC 60335 series); Also excluded from the scope of this document is AC single-phase equipment with a rated voltage higher than 250 V between phase and neutral and AC multi-phase equipment with rated voltage higher than 480 V. Abnormal operation of the equipment, such as simulated faults in the electric circuitry for testing purposes, is not taken into consideration. This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) extension of the frequency range for radiated immunity above 1 GHz; b) an advanced categorisation of equipment; c) revision of general test conditions and addition of new specific test conditions (e.g. for robotic equipment); d) clarification of requirements applicable to equipment incorporating radio functions; e) addition of requirements for wired network ports; f) revision of definitions and addition of new ones; g) delete requirements referring to statistical evaluation.