IEC 60034-27-1:2017

IEC 60034-27-1:2017

December 2017
International standard Current

Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation

IEC 60034-27-1:2017 provides a common basis for:- measuring techniques and instruments;- the arrangement of test circuits;- normalization and testing procedures;- noise reduction;- the documentation of test results;- the interpretation of test results,with respect to partial discharge off-line measurements on the winding insulation of rotating electrical machines.This International Standard cancels and replaces IEC TS 60034-27 (2006). It constitutes a technical revision and reflects numerous improvements and corrections with respect to the previous publication.

Main informations

Collections

International IEC standards

Publication date

December 2017

Number of pages

133 p.

Reference

IEC 60034-27-1:2017
Sumary
Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation

IEC 60034-27-1:2017 provides a common basis for:
- measuring techniques and instruments;
- the arrangement of test circuits;
- normalization and testing procedures;
- noise reduction;
- the documentation of test results;
- the interpretation of test results,
with respect to partial discharge off-line measurements on the winding insulation of rotating electrical machines.
This International Standard cancels and replaces IEC TS 60034-27 (2006). It constitutes a technical revision and reflects numerous improvements and corrections with respect to the previous publication.
Replaced standards (1)
IEC TS 60034-27:2006
December 2006
Technical specification Cancelled
Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines

Provides a common basis for measuring techniques and instruments, the arrangement of test circuits, normalization and testing procedures, noise reduction, the documentation of test results, the interpretation of test results with respect to partial discharge off-line measurements on the stator winding insulation of rotating electrical machines.