IEC 60060-1:2025
High-voltage test techniques - Part 1: General terminology and test requirements
IEC 60060-1:2025 is applicable to:- dielectric tests with direct voltage;- dielectric tests with alternating voltage;- dielectric tests with impulse voltage;- dielectric tests with combinations of the above.This document is applicable to tests on equipment having its highest voltage for equipment Um above 1,0 kV AC and 1,5 kV DC.This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:- The general layout and text have been updated and improved to make the standard easier to use, particularly the clauses for combined and composite test voltages.- The positive tolerance of the front time of lightning impulse voltage has been extended for Um > 800 kV to 100 % (= 2,4 µs).- For switching impulse voltage, a front time has been introduced, similar to lightning impulse voltage and with the new front time the standard switching impulse is defined as 170/2 500 µs.- The requirements for precipitations have been adjusted depending on Um.- A new Annex C, "Procedure for manual calculation from graphical waveforms" has been incorporated.- No examples of software have been given in Annex D, "Guidance for implementing software for evaluation of lightning impulse voltage parameters".- The annex relating to the "Background to the introduction of the test voltage factor for evaluation of impulses with overshoot" has been deleted.- A new informative Annex F, "New definition of the front time of switching impulse voltage" has been incorporated.NOTE 1?Alternative test procedures can be required to obtain reproducible and significant results. The choice of a suitable test procedure is considered by the relevant Technical Committee.NOTE 2?For voltages Um above 800 kV it is possible that some specified procedures, tolerances and uncertainties will not be achievable.
IEC 60060-1:2025 is applicable to:
- dielectric tests with direct voltage;
- dielectric tests with alternating voltage;
- dielectric tests with impulse voltage;
- dielectric tests with combinations of the above.
This document is applicable to tests on equipment having its highest voltage for equipment Um above 1,0 kV AC and 1,5 kV DC.
This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- The general layout and text have been updated and improved to make the standard easier to use, particularly the clauses for combined and composite test voltages.
- The positive tolerance of the front time of lightning impulse voltage has been extended for Um > 800 kV to 100 % (= 2,4 µs).
- For switching impulse voltage, a front time has been introduced, similar to lightning impulse voltage and with the new front time the standard switching impulse is defined as 170/2 500 µs.
- The requirements for precipitations have been adjusted depending on Um.
- A new Annex C, "Procedure for manual calculation from graphical waveforms" has been incorporated.
- No examples of software have been given in Annex D, "Guidance for implementing software for evaluation of lightning impulse voltage parameters".
- The annex relating to the "Background to the introduction of the test voltage factor for evaluation of impulses with overshoot" has been deleted.
- A new informative Annex F, "New definition of the front time of switching impulse voltage" has been incorporated.
NOTE 1?Alternative test procedures can be required to obtain reproducible and significant results. The choice of a suitable test procedure is considered by the relevant Technical Committee.
NOTE 2?For voltages Um above 800 kV it is possible that some specified procedures, tolerances and uncertainties will not be achievable.
IEC 60060-1:2010 applies to dielectric tests with alternating voltage; dielectric tests with direct voltage; dielectric tests with impulse voltage and dielectric tests with combinations of the above. This document is applicable to tests on equipment having its highest voltage for equipment Um above 1 kV. The third edition cancels and replaces the second edition, published in 1989, and constitutes a technical revision. The major technical changes with respect to the previous edition are as follows: - artifical pollution test procedures were removed as they are now described in IEC 60507, - measurement of impulse current has been transferred to a new standard on current measurement (IEC 62475), - the atmospheric correction factors are now presented as formulas.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ