IEC 60060-2:2010

IEC 60060-2:2010

November 2010
International standard Cancelled

High-voltage test techniques - Part 2: Measuring systems

IEC 60060-2:2010 is applicable to complete measuring systems, and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages as specified in IEC 60060-1. For measurements during on-site tests see IEC 60060-3. The limits on uncertainties of measurements stated in this standard apply to test levels stated in IEC 60071-1:2006. The principles of this standard apply also to higher levels but the uncertainty may be greater. This standard also defines the terms used, methods to estimate the uncertainties of high-voltage measurements, states the requirements which the measuring systems shall meet, describes the methods for approving a measuring system and checking its components and describes the procedures by which the user shall show that a measuring system meets the requirements of this standard, including the limits set for the uncertainty of measurement. This third edition cancels and replaces the second edition, published in 1994, and constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows:- The general layout and text was updated and improved to make the standard easier to use.- The standard was revised to align it with IEC 60060-1.- The treatment of measurement uncertainty estimation has been expanded.

Main informations

Collections

International IEC standards

Publication date

November 2010

Number of pages

149 p.

Reference

IEC 60060-2:2010
Sumary
High-voltage test techniques - Part 2: Measuring systems

IEC 60060-2:2010 is applicable to complete measuring systems, and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages as specified in IEC 60060-1. For measurements during on-site tests see IEC 60060-3. The limits on uncertainties of measurements stated in this standard apply to test levels stated in IEC 60071-1:2006. The principles of this standard apply also to higher levels but the uncertainty may be greater. This standard also defines the terms used, methods to estimate the uncertainties of high-voltage measurements, states the requirements which the measuring systems shall meet, describes the methods for approving a measuring system and checking its components and describes the procedures by which the user shall show that a measuring system meets the requirements of this standard, including the limits set for the uncertainty of measurement. This third edition cancels and replaces the second edition, published in 1994, and constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows:
- The general layout and text was updated and improved to make the standard easier to use.
- The standard was revised to align it with IEC 60060-1.
- The treatment of measurement uncertainty estimation has been expanded.
Replaced standards (2)
IEC 60060-2:1994
November 1994
International standard Cancelled
High voltage test techniques - Part 2: Measuring systems

Is applicable to complete Measuring Systems, and to their components, used for the measurement of high-voltages and currents during tests with direct voltage, alternating voltage, lightning and switching impulse voltages and for tests with impulse currents, or with combinations ot them as specified in IEC 60-1. Replaces IEC 60-3 and 60-4.

International standard Cancelled
Amendment 1 - High voltage test techniques - Part 2: Measuring systems

Standard replaced by (1)
IEC 60060-2:2025
April 2025
International standard Current
High-voltage test techniques - Part 2: Measuring systems

IEC 60060-2:2025 is applicable to complete measuring systems and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages and combined and composite voltages as specified in IEC 60060-1. For measurements during on-site tests, see IEC 60060-3. The limits on uncertainties of measurements stated in this document apply to test levels stated in IEC 60071-1. The principles of this document apply also to higher levels but the uncertainty can be greater. This document: ? defines the terms used; ? describes methods to estimate the uncertainties of high-voltage measurements; ? states the requirements that apply to measuring systems; ? describes the methods for approving a measuring system and checking its components; ? describes the procedures by which the user demonstrates that a measuring system meets the requirements of this document, including the limits set for the uncertainty of measurement. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) The general layout and text has been updated and improved to make the standard easier to use. b) This document has been revised to align it with the fourth edition of IEC 60060-1. c) The treatment of measurement uncertainty estimation has been expanded. d) This document is now applicable to measuring systems used in testing at all standard insulation levels specified in IEC 60071-1. e) The measurement uncertainty requirement for the front time of the standard lighting impulse voltage has been changed from 10 % to 15 %, for testing at all standard insulation levels specified in IEC 60071-1. f) The parameter "time-to-peak" of the switching impulse defined in the third edition of IEC 60060-1:2010 has been replaced by "front time" in the fourth edition of IEC 60060-1. Necessary changes have been made in this document to accommodate this change in IEC 60060-1. g) Clause 10, Measurement of combined voltages and Clause 11, Measurement of composite voltages have been added. h) Clause B.1 has been significantly revised to align more closely with the provisions of Clause 5, including using the same nomenclature.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ