IEC 60079-0:1983

IEC 60079-0:1983

January 1983
International standard Cancelled

Electrical apparatus for explosive gas atmospheres. Part 0: General requirements

Specifies general requirements for construction, testing andmarking of electrical apparatus for explosive gas atmospheres.Applies to electrical apparatus where atmospheric conditions forthe explosion characteristics of the explosive gas atmosphere areconsidered as having pressures in the range 80 kPa (0.8 bar) to 110kPa (1.1 bar) at a temperature in the range -20°C to +60°C.Atmospheric conditions outside this range may need specialconsideration.Does not apply to devices whose stated electrical parameters do notexceed any of the values 1-2 V, 0.1 A, 20 µJ or 25 mW, which neednot be certified or marked as required by IEC 79. However, suchdevices are subject to the requirements of the various parts of IEC79 if they are connected to a device which contains a source or astorage element of electrical energy which could cause the circuitto exceed these parameters.Supersedes IEC 79-8 and 79-9.

Main informations

Collections

International IEC standards

Thematics

QSE, Sécurité, Gestion des risques et SST

Publication date

January 1983

Number of pages

61 p.

Reference

IEC 60079-0:1983

ICS Codes

29.260.20   Electrical apparatus for explosive atmospheres

Print number

1
Sumary
Electrical apparatus for explosive gas atmospheres. Part 0: General requirements

Specifies general requirements for construction, testing and marking of electrical apparatus for explosive gas atmospheres. Applies to electrical apparatus where atmospheric conditions for the explosion characteristics of the explosive gas atmosphere are considered as having pressures in the range 80 kPa (0.8 bar) to 110 kPa (1.1 bar) at a temperature in the range -20°C to +60°C. Atmospheric conditions outside this range may need special consideration. Does not apply to devices whose stated electrical parameters do not exceed any of the values 1-2 V, 0.1 A, 20 µJ or 25 mW, which need not be certified or marked as required by IEC 79. However, such devices are subject to the requirements of the various parts of IEC 79 if they are connected to a device which contains a source or a storage element of electrical energy which could cause the circuit to exceed these parameters. Supersedes IEC 79-8 and 79-9.
Replaced standards (4)
IEC 60079-0:1971
January 1971
International standard Cancelled
Electrical apparatus for explosive gas atmospheres - Part 0: General introduction

Specifies general requirements for construction, testing and marking of electrical apparatus for explosive gas atmospheres. Applies to electrical apparatus where atmospheric conditions for the explosion characteristics of the explosive gas atmosphere are considered as having pressures in the range 80 kPa (0.8 bar) to 110 kPa (1.1 bar) at a temperature in the range -20°C to +60°C. Atmospheric conditions outside this range may need special consideration. Does not apply to devices whose stated electrical parameters do not exceed any of the values 1-2 V, 0.1 A, 20 µJ or 25 mW, which need not be certified or marked as required by IEC 79. However, such devices are subject to the requirements of the various parts of IEC 79 if they are connected to a device which contains a source or a storage element of electrical energy which could cause the circuit to exceed these parameters. Replaces IEC 79-8 and 79-9.

IEC 60079-8:1969
January 1969
International standard Cancelled
Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures

International standard Cancelled
Amendment 1 - Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures

IEC 60079-9:1970
January 1970
International standard Cancelled
Electrical apparatus for explosive gas atmospheres - Part 9: Marking

See more
Standard replaced by (1)
IEC 60079-0:1998
April 1998
International standard Cancelled
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements

Specifies the general requirements for construction, testing and marking of electrical apparatus, Ex cable entries and Ex components, intended for use in potentially explosive atmospheres of gas, vapour and mist. This standard does not specify requirements for safety, other than those directly related to the explosion risk.