IEC 60079-0:2007
Explosive atmospheres - Part 0: Equipment - General requirements
Specifies the general requirements for construction, testing and marking of electrical apparatus and Ex components intended for use in explosive gas atmospheres. Electrical apparatus complying with this standard is intended for use in hazardous areas in which explosive gas atmospheres, caused by mixtures of air and gases, vapours or mists, exist under normal atmospheric conditions. The significant changes with respect to the previous edition are: Requirements for explosive dust atmospheres transferred from IEC 61241-0, The marking Group "II" alone has been replaced by "IIA", "IIB", or "IIC" as many of the enclosure requirements are now aligned with a specific sub-group, Dust groups defined as Group IIIA, IIIB and IIIC, Remainder of "electrostatic" requirements transferred from IEC 60079-26 and Equipment protection levels (EPL) introduced.The contents of the interpretation sheets of November 2008 and April 2019, and the corrigendum of December 2010 have been included in this copy.
Specifies the general requirements for construction, testing and marking of electrical apparatus and Ex components intended for use in explosive gas atmospheres. Electrical apparatus complying with this standard is intended for use in hazardous areas in which explosive gas atmospheres, caused by mixtures of air and gases, vapours or mists, exist under normal atmospheric conditions. The significant changes with respect to the previous edition are: Requirements for explosive dust atmospheres transferred from IEC 61241-0, The marking Group "II" alone has been replaced by "IIA", "IIB", or "IIC" as many of the enclosure requirements are now aligned with a specific sub-group, Dust groups defined as Group IIIA, IIIB and IIIC, Remainder of "electrostatic" requirements transferred from IEC 60079-26 and Equipment protection levels (EPL) introduced.
The contents of the interpretation sheets of November 2008 and April 2019, and the corrigendum of December 2010 have been included in this copy.
Subscribe to IEC 60061 Database to access the full and updated content of the series.
Specifies the general requirements for construction, testing and marking of electrical apparatus and Ex components intended for use in explosive gas atmospheres. Electrical apparatus complying with this standard is intended for use in hazardous areas in which explosive gas atmospheres, caused by mixtures of air and gases, vapours or mists, exist under normal atmospheric conditions.
IEC 60079-0:2011 specifies the general requirements for construction, testing and marking of electrical equipment and Ex Components intended for use in explosive atmospheres. Electrical equipment complying with this standard is intended for use in hazardous areas in which explosive gas atmospheres, caused by mixtures of air and gases, vapours or mists, exist under normal atmospheric conditions. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed that electrical equipment can be operated are: - temperature -20 °C to +60 °C; - pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and - air with normal oxygen content, typically 21 % v/v. This standard and other standards supplementing this standard specify additional test requirements for equipment operating outside the standard temperature range, but further additional consideration and additional testing may be required for equipment operating outside the standard atmospheric pressure range and standard oxygen content, particularly with respect to types of protection that depend on quenching of a flame such as 'flameproof enclosure "d"' (IEC 60079-1) or limitation of energy, 'intrinsic safety "i"' (IEC 60079-11). This sixth edition cancels and replaces the fifth edition, published in 2007, and constitutes a full technical revision with numerous updates. IEC 60079-0:2011 is also available as <a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/931939? opendocument">IEC Standards+ 60079-0:2011 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. The contents of the corrigenda of November 2012 and December 2013, and the interpretation sheets of November 2013, October 2014, June 2018 and April 2019 have been included in this copy.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ