IEC 60079-0:2026

IEC 60079-0:2026

June 2026
International standard Current

Explosive atmospheres - Part 0: Equipment - General requirements

IEC 60079-0:2026 is available as IEC 60079-0:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60079-0:2026 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in or associated with explosive atmospheres.The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) for Ex Equipment are:- temperature −20 °C to +60 °C;- pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and- air with normal oxygen content, typically a volume fraction of 21 %.This IEC 60079-0:2026 and other documents supplementing this document specify additional test requirements for Ex Equipment operating outside the standard temperature range, but in some cases, further additional consideration and additional testing is required for Ex Equipment operating outside the standard atmospheric pressure range and standard oxygen content. Such additional testing is particularly relevant with respect to Types of Protection that depend on quenching of a flame such as 'flameproof enclosures "d"' (IEC 60079-1) or limitation of energy, 'intrinsic safety "i"' (IEC 60079-11). This eighth edition cancels and replaces the seventh edition, published in 2017. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 8.0 and the previous edition of the document.

Main informations

Collections

International IEC standards

Thematics

QSE, Sécurité, Gestion des risques et SST

Publication date

June 2026

Number of pages

159 p.

Reference

IEC 60079-0:2026

ICS Codes

29.260.20   Electrical apparatus for explosive atmospheres
Sumary
Explosive atmospheres - Part 0: Equipment - General requirements

IEC 60079-0:2026 is available as IEC 60079-0:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60079-0:2026 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in or associated with explosive atmospheres.
The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) for Ex Equipment are:
- temperature −20 °C to +60 °C;
- pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and
- air with normal oxygen content, typically a volume fraction of 21 %.
This IEC 60079-0:2026 and other documents supplementing this document specify additional test requirements for Ex Equipment operating outside the standard temperature range, but in some cases, further additional consideration and additional testing is required for Ex Equipment operating outside the standard atmospheric pressure range and standard oxygen content. Such additional testing is particularly relevant with respect to Types of Protection that depend on quenching of a flame such as 'flameproof enclosures "d"' (IEC 60079-1) or limitation of energy, 'intrinsic safety "i"' (IEC 60079-11). This eighth edition cancels and replaces the seventh edition, published in 2017. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 8.0 and the previous edition of the document.

Replaced standards (3)
IEC 60079-0:2017
December 2017
International standard Cancelled
Explosive atmospheres - Part 0: Equipment - General requirements

IEC 60079-0:2017 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed that Ex Equipment can be operated are: -temperature –20 °C to +60 °C; -pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and -air with normal oxygen content, typically 21 % v/v. This part of IEC 60079 and other standards supplementing this standard specify additional test requirements for Ex Equipment operating outside the standard temperature range, but further additional consideration and additional testing may be required for Ex Equipment operating outside the standard atmospheric pressure range and standard oxygen content. Such additional testing may be particularly relevant with respect to Types of Protection that depend on quenching of a flame such as ‘flameproof enclosures “d”’ (IEC 60079-1) or limitation of energy, ‘intrinsic safety “i”’ (IEC 60079-11). This seventh edition cancels and replaces the sixth edition, published in 2011. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 7.0 and the previous edition of the document. Keywords: Ex Equipment and Ex Components intended for use in explosive atmospheres The contents of the interpretation sheet 1 of April 2019, of the interpretation sheet 2 of June 2019 and the corrigendum 1 of January 2020 have been included in this copy.

International standard Cancelled
Corrigendum 1 - Explosive atmospheres - Part 0: Equipment - General requirements

International standard Cancelled
Interpretation Sheet 1 - Explosive atmospheres - Part 0: Equipment - General requirements

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ