IEC 60079-14:2024

IEC 60079-14:2024

August 2024
International standard Current

Explosive atmospheres - Part 14: Electrical installation design, selection and installation of equipment, including initial inspection

IEC 60079:2024 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.These requirements are in addition to the requirements for installations in non-hazardous areas.This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.This document does not apply to:? electrical installations in mines susceptible to firedamp;? inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);? rooms used for medical purposes;? electrical installations in areas where the hazard is due to flammable mist; and? installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46).No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document.This sixth edition cancels and replaces the fifth edition published in 2013. This edition constitutes a technical revision. Edition 6 is a major restructure and introduces a number of technical changes from the previous edition (2013), see Table 1 of the foreword for detailed information.

Main informations

Collections

International IEC standards

Publication date

August 2024

Number of pages

300 p.

Reference

IEC 60079-14:2024
Sumary
Explosive atmospheres - Part 14: Electrical installation design, selection and installation of equipment, including initial inspection

IEC 60079:2024 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.
These requirements are in addition to the requirements for installations in non-hazardous areas.
This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.
This document does not apply to:
? electrical installations in mines susceptible to firedamp;
? inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
? rooms used for medical purposes;
? electrical installations in areas where the hazard is due to flammable mist; and
? installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46).
No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document.
This sixth edition cancels and replaces the fifth edition published in 2013. This edition constitutes a technical revision. Edition 6 is a major restructure and introduces a number of technical changes from the previous edition (2013), see Table 1 of the foreword for detailed information.
Replaced standards (4)
IEC 60079-14:2013
November 2013
International standard Cancelled
Explosive atmospheres - Part 14: Electrical installations design, selection and erection

IEC 60079-14:2013 contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associated with, explosive atmospheres. Where the equipment is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional protection requirements may be necessary. The requirements of this standard apply only to the use of equipment under standard atmospheric conditions as defined in IEC 60079-0. For other conditions, additional precautions may be necessary, and the equipment should be certified for these other conditions. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. These requirements are in addition to the requirements for installations in non-hazardous areas. This standard applies to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary. No account is taken in this Standard of the toxic risks that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower explosive limit. In locations where personnel may be exposed to potentially toxic concentrations of flammable material, appropriate precautions should be taken. Such precautions are outside the scope of this Standard. This fifth edition cancels and replaces the fourth edition published in 2007. This edition constitutes a technical revision. Refer to the document's Foreward for a listing of the specific revisions and additional Notes. Key words: requirements for the design, selection, erection and initial inspection of electrical installations in explosive atmospheres. The contents of the corrigendum of January 2016, the interpretation sheet 1 of February 2017 and March 2020 have been included in this copy.

International standard Current
Interpretation sheet 2 of standard IEC 60079-14:2013

IEC 60079-14-F1:2017
February 2017
International standard Current
Interpretation sheet 1 of standard IEC 60079-14:2013

International standard Cancelled
Corrigendum 1 - Explosive atmospheres - Part 14: Electrical installations design, selection and erection

See more