IEC 60079-17:2007

IEC 60079-17:2007

August 2007
International standard Cancelled

Explosive atmospheres - Part 17: Electrical installations inspection and maintenance

This part of IEC 60079 applies to users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only, where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings. It does not apply to underground mining areas, areas where a risk can arise due to the presence of hybrid mixtures, dusts of explosives that do not require atmospheric oxygen for combustion, and pyrophoric substances. The significant technical changes with respect to the previous edition are as follows: Additional requirements for inspection and maintenance of electrical installations for combustible dusts and Equipment Protection Levels have been introduced and are explained in the new Annex C.

Main informations

Collections

International IEC standards

Publication date

August 2007

Number of pages

74 p.

Reference

IEC 60079-17:2007

Print number

4 - 26/09/2007
Sumary
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance

This part of IEC 60079 applies to users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only, where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings. It does not apply to underground mining areas, areas where a risk can arise due to the presence of hybrid mixtures, dusts of explosives that do not require atmospheric oxygen for combustion, and pyrophoric substances. The significant technical changes with respect to the previous edition are as follows: Additional requirements for inspection and maintenance of electrical installations for combustible dusts and Equipment Protection Levels have been introduced and are explained in the new Annex C.
Replaced standards (1)
IEC 61241-17:2005
January 2005
International standard Cancelled
Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)

This part of IEC 61241 is intended to be applied by users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only. It does not include conventional requirements for electrical installations, nor the testing and certification of electrical apparatus. This standard supplements the requirements laid down in IEC 60364-6-61. NOTE: The text is based on IEC 60079-17

Standard replaced by (1)
IEC 60079-17:2013
November 2013
International standard Cancelled
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance

IEC 60079-17:2013 applies to users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only, where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings. It does not include: - other fundamental installation and inspection requirements for electrical installations; - the verification of electrical equipment; - the repair and reclamation of explosion protected equipment (see IEC 60079-19). This standard supplements the requirements of IEC 60364-6. In the case of dusts, fibres or flyings the level of housekeeping may influence the inspection and maintenance requirements. This standard is intended to be applied where there can be a risk due to the presence of explosive gas or dust mixtures with air or combustible dust layers under normal atmospheric conditions. It does not apply to: - underground mining areas, - dusts of explosives that do not require atmospheric oxygen for combustion, - pyrophoric substances. This fifth edition cancels and replaces the fourth edition published in 2007 and constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows: - Equipment specific inspection tables for luminaires, heating systems and motors have been added into Annex A to supplement the general protection concept tables; - Document has been updated to complement the changes made to IEC 60079-14 for initial inspection. Keywords: inspection and maintenance of electrical installations within hazardous area, flammable gases, vapours, mists, dusts, fibres or flyings This publication is to be read in conjunction with IEC 60364-6:2006.