Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"

IEC 60079-18:2014+A1:2017 gives the specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components with the type of protection encapsulation "m" intended for use in explosive gas atmospheres or explosive dust atmospheres. This part applies only for encapsulated electrical equipment, encapsulated parts of electrical equipment and encapsulat ed Ex components (hereinafter always referred to as "m" equipment) where the rated voltage does not exceed 11 kV. The application of electrical equipment in atmospheres, which may contain explosive gas as well as combustible dust simultaneously, may require additional protective measures. This standard does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fourth edition cancels and replaces the third edition of IEC 60079-18:2009, and constitutes a technical revision. Please refer to the foreword of the document for a listing of the technical changes with respect to the previous edition.This publication is to be read in conjunction with IEC 60079-0:2011.This consolidated version of the official IEC Standard and its amendment contains the fourth edition (2014) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.Keywords: encapsulation "m", explosive gas atmospheres, explosive dust atmospheresThe contents of the corrigendum of July 2018 have been included in this copy.

Main informations

Collections

International IEC standards

Thematics

QSE, Sécurité, Gestion des risques et SST

Publication date

August 2017

Number of pages

145 p.

Reference

IEC 60079-18:2014+AMD1:2017 CSV

ICS Codes

29.260.20   Electrical apparatus for explosive atmospheres

Print number

1
Sumary
Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"

IEC 60079-18:2014+A1:2017 gives the specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components with the type of protection encapsulation "m" intended for use in explosive gas atmospheres or explosive dust atmospheres. This part applies only for encapsulated electrical equipment, encapsulated parts of electrical equipment and encapsulat ed Ex components (hereinafter always referred to as "m" equipment) where the rated voltage does not exceed 11 kV. The application of electrical equipment in atmospheres, which may contain explosive gas as well as combustible dust simultaneously, may require additional protective measures. This standard does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fourth edition cancels and replaces the third edition of IEC 60079-18:2009, and constitutes a technical revision. Please refer to the foreword of the document for a listing of the technical changes with respect to the previous edition.
This publication is to be read in conjunction with IEC 60079-0:2011.
This consolidated version of the official IEC Standard and its amendment contains the fourth edition (2014) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.
Keywords: encapsulation "m", explosive gas atmospheres, explosive dust atmospheres
The contents of the corrigendum of July 2018 have been included in this copy.
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ