IEC 60079-31:2008/COR1:2009

IEC 60079-31:2008/COR1:2009

March 2009
International standard Cancelled

Corrigendum 1 - Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"

Main informations

Collections

International IEC standards

Publication date

March 2009

Number of pages

0 p.

Reference

IEC 60079-31:2008/COR1:2009

Print number

1 - 11/03/2010
Standard replaced by (1)
IEC 60079-31:2013
November 2013
International standard Cancelled
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"

IEC 60079-31:2013 is applicable to electrical equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of electrical equipment and Ex Components. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This standard does not apply to electrical equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust. Consideration of additional protective measures is required where the application of electrical equipment is in atmospheres, which can contain combustible dust as well as explosive gas, whether simultaneously or separately. Where the electrical equipment has to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional measures can be necessary. The measures used should not adversely affect the integrity of the enclosure. This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. The major technical changes include: - The marked maximum surface temperature shall be measured on the external surfaces of the enclosure and the surfaces of the internal components for equipment with types of protection "ta"; - Additional protection for arcing and sparking parts for "ta"; - Test for internal enclosure for level "ta" added. Keywords: explosive dust atmospheres The contents of the Interpretation Sheet 1 of February 2022 have been included in this copy. This publication is to be read in conjunction with IEC 60079-0:2011.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ