IEC 60086-2:2006
Primary batteries - Part 2: Physical and electrical specifications
This part of IEC 60086 is applicable to primary batteries based on standardized electrochemical systems. It specifies the physical dimensions, and the discharge test conditions and discharge performance requirements. The major technical changes are the addition of a "digital still camera test" for the LR6 battery, the reduction, for selected no letter batteries, from three grades (S, C and P) to two grades (S and P) with appropriate adjustments to MAD values, the deletion of the 3,6 ohm pulse test for the R03 battery, and the addition of new constant current hearing aid tests (standard and high drain) for the PR41, PR44, PR48 and PR70 batteries.
This part of IEC 60086 is applicable to primary batteries based on standardized electrochemical systems. It specifies the physical dimensions, and the discharge test conditions and discharge performance requirements. The major technical changes are the addition of a "digital still camera test" for the LR6 battery, the reduction, for selected no letter batteries, from three grades (S, C and P) to two grades (S and P) with appropriate adjustments to MAD values, the deletion of the 3,6 ohm pulse test for the R03 battery, and the addition of new constant current hearing aid tests (standard and high drain) for the PR41, PR44, PR48 and PR70 batteries.
Applicable to primary batteries based on standardized electrochemical systems, it specifies the physical dimensions, the discharge test conditions, and the discharge performance requirements.
IEC 60086-2:2011 is applicable to primary batteries based on standardized electrochemical systems. It specifies the physical dimensions; and the discharge test conditions and discharge performance requirements. Significant changes from the previous edition are the deletion of eight battery types from this standard, the addition of an air hole placement diagram and deletion of the resistive hearing aid tests for the P-system (zinc air) hearing aid batteries, standardization of a new form of alkaline (L-system) 9 volt battery (6LP3146), addition of a common designation reference as Annex D and general adjustment of application tests and their minimum average duration values to reflect changes in battery usage.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ