IEC 60118-0:2015
Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids
IEC 60118-0:2015 gives recommendations for the measurement of the performance characteristics of air conduction hearing aids based on a free field technique and measured with an acoustic coupler. This third edition cancels and replaces the second edition published in 1983 and its Amendment 1:1994 as well as IEC 60118-1:1995, Amendment 1:1998, IEC 60118-2:1983, Amendment 1:1993, Amendment 2:1997 and IEC 60118-6:1999. This edition constitutes a technical revision.
IEC 60118-0:2015 gives recommendations for the measurement of the performance characteristics of air conduction hearing aids based on a free field technique and measured with an acoustic coupler. This third edition cancels and replaces the second edition published in 1983 and its Amendment 1:1994 as well as IEC 60118-1:1995, Amendment 1:1998, IEC 60118-2:1983, Amendment 1:1993, Amendment 2:1997 and IEC 60118-6:1999. This edition constitutes a technical revision.
Adds a new clause 10 to IEC 60118-2 second edition : Frequency response of hearing heads with AGC circuits in operation using steady-state broad-band signals.
Adds a new clause 9 to IEC 60118-2 second edition: AGC activated frequency response of hearing aids with a single channel AGC circuit in operation using pure tone signals.
Gives uniform methods for specifying dynamic and static performance characteristics of hearing aids with automatic gain control circuits together with the relevant methods of measurement for these characteristics.
Replaces clause 4.17 of IEC 60118-0 second edition by a new one.
Specifies a method of determining the electroacoustic performance of hearing aids fitted with an induction pick-up coil and used in an audio-frequency magnetic field. The induction pick-up performance is measured in a loop simulating conditions of use in room applications.
Specifies the electrical and safety characteristics of a circuit for an external electrical input to a personal hearing aid in order to ensure compatibility with external electrical or electroacoustic signal sources. In this standard, the hearing aid may include an adaptor (audio shoe) which incorporates connector systems described in IEC 60118-12.
Defines the measurement of physical performance characteristics of air-conduction hearing aids based on a free-field technique and measured with an ear simulator. Describes methods of measurement for evaluation of the electroacoustical characteristics of hearing aids.
IEC 60118-0:2022 gives recommendations for the measurement of the performance characteristics of air conduction hearing aids measured with an acoustic coupler or occluded ear simulator. This document is applicable to the measurement and evaluation of the electroacoustical characteristics of hearing aids, for example for type testing and manufacturer data sheets. This document is also applicable for the measurement of the performance characteristics of hearing aids for production, supply and delivery quality-assurance purposes. The measurement results obtained by the methods specified in this document will express the performance under conditions of the measurement and can deviate substantially from the performance of the hearing aid under actual conditions of use. This document primarily uses an acoustic coupler according to IEC 60318-5 which is only intended for loading a hearing aid with specified acoustic impedance and is not intended to reproduce the sound pressure in a person's ear. For measurements reflecting the output level in the normal human ear the occluded ear simulator according to IEC 60318-4 can be used. For extended high-frequency measurements and for deep insert hearing aids, the acoustic coupler according to IEC 60318-8 can be used. This document also covers measurement of hearing aids with non-acoustic inputs, such as wireless, inductive or electrical input. This document does not cover the measurement of hearing aids for simulated in situ working conditions, for which IEC 60118-8 can be applied. This document does not cover the measurement of hearing aids under typical user settings and using a speech-like signal, for which IEC 60118-15 can be applied. IEC 60118-0:2022 merges and updates the methods previously described in IEC 60118-0:2015 and IEC 60118-7:2005. It cancels and replaces the third edition of IEC 60118-0 published in 2015. This edition constitutes a technical revision. Measurements for quality control as described in IEC 60118-7:2005 can be found in Clause 10 of this document. This edition includes the following significant technical changes with respect to previous editions: a) the default use of an acoustic coupler according to IEC 60318-5, b) addition of the optional use of an occluded ear simulator according to IEC 60318-4, c) addition of the optional use of an acoustic coupler according to IEC 60318-8 (new standard based on IEC TS 62886) when information about the response above 8 kHz is needed, or the optional use of the acoustic coupler according to IEC 60318-8 for deep insert hearing aids, d) the addition of measurements of the performance of hearing aids for production, supply and delivery quality assurance purposes, e) corrected and updated measurement configuration and methods, adding the use of a sequential measurement as preferred configuration, f) updated and expanded measurement procedures for the non-acoustic inputs of the hearing aid.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ