IEC 60118-9:1985
Hearing aids. Part 9: Methods of measurement of characteristics of hearing aids with bone vibrator output
Defines a method of expressing the input/output ratio as an acousto-mechanical sensitivity level measured on a mechanical coupler according to the second edition of IEC 60373. Provides a suitable basis for the exchange of information or for direct comparison of the electroacoustic characteristics of hearing aids using bone vibrator outputs. The methods chosen are practical and reproducible and are based on selected fixed parameters.
Defines a method of expressing the input/output ratio as an acousto-mechanical sensitivity level measured on a mechanical coupler according to the second edition of IEC 60373. Provides a suitable basis for the exchange of information or for direct comparison of the electroacoustic characteristics of hearing aids using bone vibrator outputs. The methods chosen are practical and reproducible and are based on selected fixed parameters.
IEC 60118-9:2019 specifies methods for the measurement of bone conduction hearing aid characteristics. The methods described will produce a suitable basis for the exchange of information or for direct comparison of the electroacoustical characteristics of bone conduction hearing aids. These methods are chosen to be practical and reproducible and are based on selected fixed parameters. The results obtained by the methods specified in this document express the performance under the conditions of measurement; however, the performance of the hearing aid under practical conditions of use will depend upon a number of factors (e.g. effective load impedance, environmental conditions, acoustical environment, etc.). This document defines methods of measurement of characteristics of bone conduction hearing aids both for • transcutaneously coupled devices measured on a mechanical coupler, meeting the requirements of IEC 60318-6, and • bone coupled/bone anchored devices measured on a skull simulator. IEC 60118-9:2019 cancels and replaces the first edition published in 1985. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) includes bone coupled devices measured on a skull simulator; b) measurement frequency range increased to 8 000 Hz for bone coupled devices.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ